LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Diagnostics Value of Quantitative Magnetic Resonance Imaging (MRI) in Neonatal Acute Bilirubin Encephalopathy

Photo from wikipedia

Background: This study was designed to investigate the diagnostic value of relative signal intensity of globus pallidus on T1-weighted magnetic resonance imaging (MRI) in neonatal acute bilirubin encephalopathy (ABE). Methods:… Click to show full abstract

Background: This study was designed to investigate the diagnostic value of relative signal intensity of globus pallidus on T1-weighted magnetic resonance imaging (MRI) in neonatal acute bilirubin encephalopathy (ABE). Methods: Participants who were recruited in hospital from April 2019 to May 2020 were grouped into mildly increased total serum bilirubin (TSB) group (n = 30), severely increased TSB group (n = 25), or extremely increased TSB group (n = 10) based on the total serum bilirubin level. Bilirubin-induced neurologic dysfunction scale score was used to determine if participants had acute bilirubin encephalopathy. All neonates underwent conventional brain MRI and the relative signal intensity of globus pallidus was measured on T1-weighted images. The diagnostic value of these 3 indices was assessed by receiver operating characteristic curve analysis. Results: There was a significant correlation between relative signal intensity of globus pallidus and total serum bilirubin level in neonates with hyperbilirubinemia (r = 0.551, P < .001). Relative signal intensity of globus pallidus in the extremely increased TSB group was significantly higher than that in severely increased TSB, mildly increased TSB, and healthy control groups. Relative signal intensity of globus pallidus in the acute bilirubin encephalopathy group was significantly higher than that in the non-acute bilirubin encephalopathy group (P < .01). The area under the receiver operating characteristic curve of the relative signal intensity of globus pallidus was 0.765 (P < .01), with sensitivity of 0.655 and specificity of 0.861. The area under the curve of the total serum bilirubin and visual inspection of globus pallidus signal was 0.621 and 0.579, respectively. The area under the curve of relative signal intensity was significantly greater than that of total serum bilirubin and visual inspection (P = .04 for both). Conclusion: Relative signal intensity of globus pallidus, which is an objective assessment, has the potential to be used as a diagnostic tool for acute bilirubin encephalopathy.

Keywords: bilirubin; signal intensity; bilirubin encephalopathy; globus pallidus; relative signal; acute bilirubin

Journal Title: Journal of Child Neurology
Year Published: 2023

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.