LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Endovascular Temporary Balloon Occlusion for Microsurgical Clipping of Posterior Circulation Aneurysms

Photo from wikipedia

Based on the relationship between the posterior clinoid process and the basilar artery (BA) apex it may be difficult to obtain proximal control of the BA using temporary clips. Endovascular… Click to show full abstract

Based on the relationship between the posterior clinoid process and the basilar artery (BA) apex it may be difficult to obtain proximal control of the BA using temporary clips. Endovascular BA temporary balloon occlusion (TBO) can reduce aneurysm sac pressure, facilitate dissection/clipping, and finally lower the risk of intraoperative rupture. We present our experience with TBO during aneurysm clipping of posterior circulation aneurysms within the setting of a hybrid operating room (hOR). We report one case each of a basilar tip, posterior cerebral artery, and superior cerebellar artery aneurysm that underwent surgical occlusion under TBO within an hOR. Surgical exposure of the BA was achieved with a pterional approach and selective anterior and posterior clinoidectomy. Intraoperative digital subtraction angiography (iDSA) was performed prior, during, and after aneurysm occlusion. Two patients presented with subarachnoid hemorrhage and one patient presented with an unruptured aneurysm. The intraluminal balloon was inserted through the femoral artery and inflated in the BA after craniotomy to allow further dissection of the parent vessel and branches needed for the preparation of the aneurysm neck. No complications during balloon inflation and aneurysm dissection occurred. Intraoperative aneurysm rupture prior to clipping did not occur. The duration of TBO varied between 9 and 11 min. Small neck aneurysm remnants were present in two cases (BA and PCA). Two patients recovered well with a GOS 5 after surgery and one patient died due to complications unrelated to surgery. Intraoperative TBO within the hOR is a feasible and safe procedure with no additional morbidity when using a standardized protocol and setting. No relevant side effects or intraoperative complications were present in this series. In addition, iDSA in an hOR facilitates the evaluation of the surgical result and 3D reconstructions provide documentation of potential aneurysm remnants for future follow-up.

Keywords: aneurysm; balloon; endovascular temporary; occlusion; tbo; temporary balloon

Journal Title: Brain Sciences
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.