LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Commissioning of a PTW 34070 large‐area plane‐parallel ionization chamber for small field megavoltage photon dosimetry

Photo from wikipedia

Abstract Purpose This study investigates a large‐area plane‐parallel ionization chamber (LAC) for measurements of dose‐area product in water (DAP w) in megavoltage (MV) photon fields. Methods Uniformity of electrode separation… Click to show full abstract

Abstract Purpose This study investigates a large‐area plane‐parallel ionization chamber (LAC) for measurements of dose‐area product in water (DAP w) in megavoltage (MV) photon fields. Methods Uniformity of electrode separation of the LAC (PTW34070 Bragg Peak Chamber, sensitive volume diameter: 8.16 cm) was measured using high‐resolution microCT. Signal dependence on angle α of beam incidence for square 6 MV fields of side length s = 20 cm and 1 cm was measured in air. Polarity and recombination effects were characterized in 6, 10, and 18 MV photons fields. To assess the lateral setup tolerance, scanned LAC profiles of a 1 × 1 cm2 field were acquired. A 6 MV calibration coefficient, ND ,w, LAC, was determined in a field collimated by a 5 cm diameter stereotactic cone with known DAP w. Additional calibrations in 10 × 10 cm2 fields at 6, 10, and 18 MV were performed. Results Electrode separation is uniform and agrees with specifications. Volume‐averaging leads to a signal increase proportional to ~1/cos(α) in small fields. Correction factors for polarity and recombination range between 0.9986 to 0.9996 and 1.0007 to 1.0024, respectively. Off‐axis displacement by up to 0.5 cm did not change the measured signal in a 1 × 1 cm2 field. ND ,w, LAC was 163.7 mGy cm−2 nC −1 and differs by +3.0% from the coefficient derived in the 10 × 10 cm2 6 MV field. Response in 10 and 18 MV fields increased by 1.0% and 2.7% compared to 6 MV. Conclusions The LAC requires only small correction factors for DAP w measurements and shows little energy dependence. Lateral setup errors of 0.5 cm are tolerated in 1 × 1 cm2 fields, but beam incidence must be kept as close to normal as possible. Calibration in 10 × 10 fields is not recommended because of the LAC's over‐response. The accuracy of relative point‐dose measurements in the field's periphery is an important limiting factor for the accuracy of DAP w measurements.

Keywords: field; plane parallel; area plane; area; parallel ionization; large area

Journal Title: Journal of Applied Clinical Medical Physics
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.