LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Patient motion tracking for non‐isocentric and non‐coplanar treatments via fixed frame‐of‐reference 3D camera

Photo from wikipedia

Abstract Purpose As C‐arm linac radiation therapy evolves toward faster, more efficient delivery, and more conformal dosimetry, treatments with increasingly complex couch motions are emerging. Monitoring the patient motion independently… Click to show full abstract

Abstract Purpose As C‐arm linac radiation therapy evolves toward faster, more efficient delivery, and more conformal dosimetry, treatments with increasingly complex couch motions are emerging. Monitoring the patient motion independently of the couch motion during non‐coplanar, non‐isocentric, or dynamic couch treatments is a key bottleneck to their clinical implementation. The goal of this study is to develop a prototype real‐time monitoring system for unconventional beam trajectories to ensure a safe and accurate treatment delivery. Methods An in‐house algorithm was developed for tracking using a couch‐mounted three‐dimensional (3D) depth camera. The accuracy of patient motion detection on the couch was tested on a 3D printed phantom created from the body surface contour exported from the treatment planning system. The technique was evaluated against a commercial optical surface monitoring system with known phantom displacements of 3, 5, and 7 mm in lateral, longitudinal, and vertical directions by placing a head phantom on a dynamic platform on the treatment couch. The stability of the monitoring system was evaluated during dynamic couch trajectories, at speeds between 10.6 and 65 cm/min. Results The proposed monitoring system agreed with the ceiling mounted optical surface monitoring system in longitudinal, lateral, and vertical directions within 0.5 mm. The uncertainty caused by couch vibration increased with couch speed but remained sub‐millimeter for speeds up to 32 cm/min. For couch speeds of 10.6, 32.2, and 65 cm/min, the uncertainty ranges were 0.27– 0.73 mm, 0.15–0.87 mm, and 0.28–1.29 mm, respectively. Conclusion By mounting a 3D camera in the same frame‐of‐reference as the patient and eliminating dead spots, this proof of concept demonstrates real‐time patient monitoring during couch motion. For treatments with non‐coplanar beams, multiple isocenters, or dynamic couch motion, this provides additional safety without additional radiation dose and avoids some of the complexity and limitations of room mounted systems.

Keywords: motion; monitoring system; patient motion; non coplanar; monitoring

Journal Title: Journal of Applied Clinical Medical Physics
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.