LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Knowledge‐based planning in robotic intracranial stereotactic radiosurgery treatments

Photo by testalizeme from unsplash

Abstract Purpose To develop a knowledge‐based planning (KBP) model that predicts dosimetric indices and facilitates planning in CyberKnife intracranial stereotactic radiosurgery/radiotherapy (SRS/SRT). Methods Forty CyberKnife SRS/SRT plans were retrospectively used… Click to show full abstract

Abstract Purpose To develop a knowledge‐based planning (KBP) model that predicts dosimetric indices and facilitates planning in CyberKnife intracranial stereotactic radiosurgery/radiotherapy (SRS/SRT). Methods Forty CyberKnife SRS/SRT plans were retrospectively used to build a linear KBP model which correlated the equivalent radius of the PTV (req_PTV) and the equivalent radius of volume that receives a set of prescription dose (req_Vi, where Vi = V10%, V20% … V120%). To evaluate the model’s predictability, a fourfold cross‐validation was performed for dosimetric indices such as gradient measure (GM) and brain V50%. The accuracy of the prediction was quantified by the mean and the standard deviation of the difference between planned and predicted values, (i.e., ΔGM = GMpred − GMclin and fractional ΔV50% = (V50%pred − V50%clin)/V50%clin) and a coefficient of determination, R2. Then, the KBP model was incorporated into the planning for another 22 clinical cases. The training plans and the KBP test plans were compared in terms of the new conformity index (nCI) as well as the planning efficiency. Results Our KBP model showed desirable predictability. For the 40 training plans, the average prediction error from cross‐validation was only 0.36 ± 0.06 mm for ΔGM, and 0.12 ± 0.08 for ΔV50%. The R2 for the linear fit between req_PTV and req_vi was 0.985 ± 0.019 for isodose volumes ranging from V10% to V120%; particularly, R2 = 0.995 for V50% and R2 = 0.997 for V100%. Compared to the training plans, our KBP test plan nCI was improved from 1.31 ± 0.15 to 1.15 ± 0.08 (P < 0.0001). The efficient automatic generation of the optimization constraints by using our model requested no or little planner’s intervention. Conclusion We demonstrated a linear KBP based on PTV volumes that accurately predicts CyberKnife SRS/SRT planning dosimetric indices and greatly helps achieve superior plan quality and planning efficiency.

Keywords: based planning; intracranial stereotactic; model; kbp model; knowledge based; stereotactic radiosurgery

Journal Title: Journal of Applied Clinical Medical Physics
Year Published: 2021

Link to full text (if available)