Abstract Purpose Implementing new online adaptive radiation therapy technologies is challenging because extra clinical resources are required particularly expert contour review. Here, we provide the first assessment of Varian's Ethos™… Click to show full abstract
Abstract Purpose Implementing new online adaptive radiation therapy technologies is challenging because extra clinical resources are required particularly expert contour review. Here, we provide the first assessment of Varian's Ethos™ adaptive platform for prostate cancer using no manual edits after auto‐segmentation to minimize this impact on clinical efficiency. Methods Twenty‐five prostate patients previously treated at our clinic were re‐planned using an Ethos™ emulator. Clinical target volumes (CTV) included intact prostate and proximal seminal vesicles. The following clinical margins were used: 3 mm posterior, 5 mm left/right/anterior, and 7 mm superior/inferior. Adapted plans were calculated for 10 fractions per patient using Ethos's auto‐segmentation and auto‐planning workflow without manual contouring edits. Doses and auto‐segmented structures were exported to our clinical treatment planning system where contours were modified as needed for all 250 CTVs and organs‐at‐risk. Dose metrics from adapted plans were compared to unadapted plans to evaluate CTV and OAR dose changes. Results Overall 96% of fractions required auto‐segmentation edits, although corrections were generally minor (<10% of the volume for 70% of CTVs, 88% of bladders, and 90% of rectums). However, for one patient the auto‐segmented CTV failed to include the superior portion of prostate that extended into the bladder at all 10 fractions resulting in under‐contouring of the CTV by 31.3% ± 6.7%. For the 24 patients with minor auto‐segmentation corrections, adaptation improved CTV D98% by 2.9% ± 5.3%. For non‐adapted fractions where bladder or rectum V90% exceeded clinical thresholds, adaptation reduced them by 13.1% ± 1.0% and 6.5% ± 7.3%, respectively. Conclusion For most patients, Ethos's online adaptive radiation therapy workflow improved CTV D98% and reduced normal tissue dose when structures would otherwise exceed clinical thresholds, even without time‐consuming manual edits. However, for one in 25 patients, large contour edits were required and thus scrutiny of the daily auto‐segmentation is necessary and not all patients will be good candidates for adaptation.
               
Click one of the above tabs to view related content.