LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Assessment of efficacy in automated plan generation for Varian Ethos intelligent optimization engine

Photo from wikipedia

Abstract Varian Ethos, a new treatment platform, is capable of automatically generating treatment plans for initial planning and for online, adaptive planning, using an intelligent optimization engine (IOE). The primary… Click to show full abstract

Abstract Varian Ethos, a new treatment platform, is capable of automatically generating treatment plans for initial planning and for online, adaptive planning, using an intelligent optimization engine (IOE). The primary purpose of this study is to assess the efficacy of Varian Ethos IOE for auto‐planning and intercompare different treatment modalities within the Ethos treatment planning system (TPS). A total of 36 retrospective prostate and proximal seminal vesicles cases were selected for this study. The prescription dose was 50.4 Gy in 28 fractions to the proximal seminal vesicles, with a simultaneous integrated boost of 70 Gy to the prostate gland. Based on RT intent, three treatment plans were auto‐generated in the Ethos TPS and were exported to the Eclipse TPS for intercomparison with the Eclipse treatment plan. When normalized for the same planning target volume (PTV) coverage, Ethos plans D max% were 108.1 ± 1.2%, 108.4 ± 1.6%, and 109.6 ± 2.0%, for the 9‐field IMRT, 12‐field IMRT, and 2‐full arc VMAT plans, respectively. This compared well with Eclipse plan D max% values, which was 108.8 ± 1.4%. OAR indices were also evaluated for Ethos plans using Radiation Therapy Oncology Group report 0415 as a guide and were found to be comparable to each other and the Eclipse plans. While all Ethos plans were comparable, we found that, in general, the Ethos 12‐field IMRT plans met most of the dosimetric goals for treatment. Also, Ethos IOE consistently generated dosimetrically hotter VMAT plans versus IMRT plans. On average, Ethos TPS took 13 min to generate 2‐full arc VMAT plans, compared to 5 min for 12‐field IMRT plans. Varian Ethos TPS can generate multiple treatment plans in an efficient time frame and the quality of the plans could be deemed clinically acceptable when compared to manually generated treatment plans.

Keywords: ethos; treatment plans; varian ethos; treatment; intelligent optimization; plan

Journal Title: Journal of Applied Clinical Medical Physics
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.