Abstract Purpose Development of an independent MU calculator (StereoCalc) with and without heterogeneity corrections for stereotactic treatments, in a Varian TrueBeam STx LINAC using stereotactic cones, with flattening filter‐free photon… Click to show full abstract

Abstract Purpose Development of an independent MU calculator (StereoCalc) with and without heterogeneity corrections for stereotactic treatments, in a Varian TrueBeam STx LINAC using stereotactic cones, with flattening filter‐free photon energies. Methods Multiple depth curves and output factors were measured, following the dosimetry formalism for small fields proposed by the TRS‐483. The developed StereoCalc imports and processes the beam data files and calculates the patient plans with and without heterogeneity correction. Validation of the developed software was carried out using phantoms. The accuracy of the StereoCalc software was verified in stereotactic patient plans. Results A maximum difference of 2.47% and 2.07% was obtained in the phantom validation tests with and without heterogeneity correction, respectively. The mean percentual difference of StereoCalc from cone dose calculation (CDC) in the clinical testing was 2.86% ±1.27% and 0.78% ±0.48% with and without heterogeneity correction, respectively. The largest differences found were 7.34% and 1.98%, respectively. Conclusions The results obtained in this work show that the MU calculated with StereoCalc software is in good agreement with the values calculated by the treatment planning systems, both in static fields and arcs. We have also improved the software to consider heterogeneity corrections calculations. As expected, and as a major achievement of this work, some differences were observed when heterogeneities were considered. StereoCalc proved to be a powerful tool that can be integrated into the specific quality assurance program in a medical physics department for independent verification in stereotactic treatment with cones.

Keywords: software; development independent; heterogeneity; stereotactic cones; without heterogeneity

Journal Title: Journal of Applied Clinical Medical Physics
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.