Impact of flexible noise control (FNC) image processing parameters on portable chest radiography

Photo by towfiqu999999 from unsplash

Abstract There is a lack of understanding in the performance of flexible noise control (FNC) processing, which is used in digital radiography on a scanner vendor and has four parameters… Click to show full abstract

Abstract There is a lack of understanding in the performance of flexible noise control (FNC) processing, which is used in digital radiography on a scanner vendor and has four parameters each involving multiple options. The aim of this study was to investigate the impact of FNC on portable chest imaging. An anthropomorphic chest phantom was imaged using a clinical chest program with 85 kV and five radiation dose levels at 40″ source‐to‐image distance with software‐based scatter reduction method. All images were processed without and with FNC. Noise analysis was performed in two regions of interest (ROI) on subtracted noise‐only images, and line profiles were generated through a lung‐rib interface. In addition, noise power spectra (NPS) analysis was performed in solid water phantoms of 10 and 20 cm thicknesses, using the same acquisition program and a range of dose levels. Last, feedback on retrospectively deidentified, reprocessed, and randomized clinical images from 20 portable chest exams was gathered from two thoracic radiologists. Noise reduction performances of FNC were demonstrated, with the level depending on specific FNC parameters, dose levels, ROI placement, and phantom sizes. Higher frequency textural patterns were revealed through the NPS analysis, which varied based on FNC parameters, dose levels, and phantom sizes. Overall, the vendor default parameter FGA0.5 yielded the highest noise reduction and textural artifacts. Radiologist feedback showed consistent preference of no FNC due to the presence of textural artifacts in the FNC‐processed images. An algorithm improvement to avoid introducing artifacts would be desired.

Keywords: noise; portable chest; dose levels; control fnc; flexible noise; noise control

Journal Title: Journal of Applied Clinical Medical Physics
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.