LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Output feedback control of a three‐phase four‐wire unified power quality conditioner

Photo from wikipedia

The increasing penetration of power electronics in electrical equipment entails a significant impact on the deterioration of power supply quality. In this paper, the problem of power quality is addressed… Click to show full abstract

The increasing penetration of power electronics in electrical equipment entails a significant impact on the deterioration of power supply quality. In this paper, the problem of power quality is addressed for distorted three‐phase four‐wire power grids supplying non‐linear unbalanced loads. A unified power quality conditioner (UPQC) is considered to ensure satisfactory electrical energy quality. To this end, a UPQC controller is designed to meet four control objectives: i) compensation of the harmonics and the reactive load currents; ii) compensation for the harmonic voltages at the point of common coupling (PCC); iii) cancelation of the neutral current; iv) and regulation of the inverter DC voltage. The control design relies on the UPQC nonlinear model that accounts for the electrical grid line impedance. Unlike previous works, the proposed controller features an output‐feedback nature as it combines a nonlinear regulator, designed with a sliding‐mode technique, and a state observer designed using a Lyapunov stability based technique. The latter provides the former with online estimates of the series filter AC voltages, which are not assumed to be accessible to measurements. The closed loop error system is analyzed using the average stability approach. It turns out that all (tracking and estimation) errors are asymptotically vanishing, except for the DC bus voltage tracking error, which is periodic in steady‐state with an amplitude depending on the (DC bus) capacitor, the larger the capacitor the smaller the steady‐state DC voltage tracking error level. This theoretical result is confirmed by simulations involving wide range variations of the load current.

Keywords: phase four; power quality; quality; power; three phase; control

Journal Title: Asian Journal of Control
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.