LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Development of transient trapping micellar electrokinetic chromatography coupled with mass spectrometry for steroids analysis.

Photo from wikipedia

An on-line sample preconcentration technique based on transient trapping (tr-trapping) in micellar electrokinetic chromatography (MEKC) was applied for steroid detection with UV (tr-trapping-UV) and electrospray ionization mass spectrometry detection (tr-trapping-ESI-MS).… Click to show full abstract

An on-line sample preconcentration technique based on transient trapping (tr-trapping) in micellar electrokinetic chromatography (MEKC) was applied for steroid detection with UV (tr-trapping-UV) and electrospray ionization mass spectrometry detection (tr-trapping-ESI-MS). ESI-MS was used to improve the sensitivity in MEKC. The MEKC separation was carried out using volatile ammonium formate as a background solution to facilitate the coupling with ESI-MS. The partial introduction of a sodium dodecyl sulfate (SDS) micellar solution before the introduction of a sample solution to the capillary provided the effective preconcentration of analytes. At the same time, the SDS micelle would not enter the ESI-MS system, so its interference in ESI-MS detection was suppressed under the optimal condition, then five steroids can be separated by the developed method. In tr-trapping-ESI-MS, an acidic condition of pH 3.5 was employed to suppress the electroosmotic flow, which can avoid micellar solution migrating to the MS instrument. The developed method showed that the micellar solution requires a twofold slower time than the sample to migrate along the column, which can prohibit the cause of the problem with the MS instrument and interference signal of SDS in the steroid's detection. The tr-trapping-ESI-MS protocol showed up to 540-fold enhancements of the peak intensity and 50-fold improvement of the limit of detection compared with capillary zone electrophoresis using androsterone as a model sample.

Keywords: trapping micellar; electrokinetic chromatography; detection; micellar electrokinetic; solution; transient trapping

Journal Title: Chirality
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.