LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Enantiomeric separation and quantification of R/S-amphetamine in serum using semi-automated liquid-liquid extraction and ultra-high performance supercritical fluid chromatography-tandem mass spectrometry.

Photo from wikipedia

The amphetamine molecule contains a chiral center and its enantiomers exhibit differences in pharmacological effects, with the S-enantiomer mediating most of the central nervous system stimulating activity. The majority of… Click to show full abstract

The amphetamine molecule contains a chiral center and its enantiomers exhibit differences in pharmacological effects, with the S-enantiomer mediating most of the central nervous system stimulating activity. The majority of prescribed amphetamine consists of the pure S-enantiomer, but therapeutic formulations containing the R-enantiomer in various proportions are also available. Illegal amphetamine remains available mainly as a racemic mixture of the R- and S-enantiomers. To distinguish between legal and illegal consumption of amphetamine a method for enantiomeric separation and quantification of R/S-amphetamine in serum was developed and validated using ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS). Sample preparation prior to UHPSFC-MS/MS analysis was performed by a semi-automated liquid-liquid extraction method. The UHPSFC-MS/MS method used a Chiralpak AD-3 column with a mobile phase consisting of CO2 and 0.1% ammonium hydroxide in 2-propanol/methanol (50/50, v/v). The injection volume was 2 μL and run time was 4 minutes. MS/MS detection was performed with positive electrospray ionization and two multiple reaction monitoring transitions (m/z 136.1 > 119.0 and m/z 136.1 > 91.0). The calibration range was 12.5-1000 nM for each analyte. The between-assay relative standard deviations were in the range of 1.3-3.0%. Recovery was 73% and matrix effects ranged from 95 to 100% when corrected with internal standard. After development and validation, the method has been successfully implemented in our laboratory for both separation and quantification of R/S-amphetamine and has proved to be a reliable and useful tool for distinguishing intake of R- and S-amphetamine in authentic patient samples.

Keywords: quantification amphetamine; enantiomeric separation; amphetamine; separation quantification

Journal Title: Drug testing and analysis
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.