Ciprofloxacin is one of the most potent fluoroquinolone antibiotics in medical treatment with a widely effective antibacterial activity. Aim of the presented paper was to use boron doped diamond electrodes… Click to show full abstract
Ciprofloxacin is one of the most potent fluoroquinolone antibiotics in medical treatment with a widely effective antibacterial activity. Aim of the presented paper was to use boron doped diamond electrodes for a sensitive, simple and reliable voltammetric determination of ciprofloxacin in human urine samples. Prior to the electrochemical analyses, an optimal boron doping level was determined in order to achieve the highest sensitivity. A set of boron doped diamond electrodes with the doping level in the range from 0 to 20 000 ppm B/C was used for this purpose. Electrochemical behavior of ciprofloxacin was investigated using cyclic voltammetry in an ammonium acetate buffer (pH 5), where ciprofloxacin provided a well-defined irreversible oxidation peak at a potential of + 1.15 V. Under optimal experimental conditions, the calibration curve obtained by square-wave voltammetry was linear in a concentration range from 0.15 to 2.11 μmol/L (R2=0.9974). A very low limit of detection (0.05 μmol/L) was obtained for the BDD electrode with the highest doping level. The developed square wave method was successfully applied to the determination of ciprofloxacin in human urine samples with a very good recovery (from 97 to 102%).
               