Design of experiments as a valuable tool for biopharmaceutical analysis with (imaged) capillary isoelectric focusing

Photo by sxy_selia from unsplash

Capillary isoelectric focusing is indispensable for characterizing charge heterogeneity and isoelectric points of biopharmaceuticals. However, there are many influencing parameters and therefore method development is challenging. This study was performed… Click to show full abstract

Capillary isoelectric focusing is indispensable for characterizing charge heterogeneity and isoelectric points of biopharmaceuticals. However, there are many influencing parameters and therefore method development is challenging. This study was performed to obtain an in‐depth understanding of the imaged CIEF methodology by applying a design of experiments approach. To describe the parameter's effects as objectively as possible, a polynomial regression model was derived for the most important responses. For this purpose, the reference monoclonal antibody suggested by the National Institute of Standards and Technology (NISTmAb) was used as test molecule. The total concentration and the mixing ratio of two types of carrier ampholytes and the added amounts of urea and l‐arginine were selected as factors. The effects of these factors on 13 different responses such as resolution or pI values were investigated. In order to reduce the total number of experiments, a d‐optimal design with 20 different parameter combinations and six replicates each was chosen. The most significant effects of the four factors were shown for the parameters related to separation efficiency and peak position. In addition, the extent of the factor's effect could be assessed. Depending on the selected factor combination, the pI value can differ up to approximately 0.15 pI units and the resolution value between main peak and adjacent basic peak can range from approximately 1.6 to 2.5, for example.

Keywords: capillary isoelectric; experiments valuable; valuable tool; design experiments; isoelectric focusing; design

Journal Title: ELECTROPHORESIS
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.