LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Automated quality assessment of structural magnetic resonance images in children: Comparison with visual inspection and surface‐based reconstruction

Photo by thisisengineering from unsplash

Motion‐related artifacts are one of the major challenges associated with pediatric neuroimaging. Recent studies have shown a relationship between visual quality ratings of T1 images and cortical reconstruction measures. Automated… Click to show full abstract

Motion‐related artifacts are one of the major challenges associated with pediatric neuroimaging. Recent studies have shown a relationship between visual quality ratings of T1 images and cortical reconstruction measures. Automated algorithms offer more precision in quantifying movement‐related artifacts compared to visual inspection. Thus, the goal of this study was to test three different automated quality assessment algorithms for structural MRI scans. The three algorithms included a Fourier‐, integral‐, and a gradient‐based approach which were run on raw T1‐weighted imaging data collected from four different scanners. The four cohorts included a total of 6,662 MRI scans from two waves of the Generation R Study, the NIH NHGRI Study, and the GUSTO Study. Using receiver operating characteristics with visually inspected quality ratings of the T1 images, the area under the curve (AUC) for the gradient algorithm, which performed better than either the integral or Fourier approaches, was 0.95, 0.88, and 0.82 for the Generation R, NHGRI, and GUSTO studies, respectively. For scans of poor initial quality, repeating the scan often resulted in a better quality second image. Finally, we found that even minor differences in automated quality measurements were associated with FreeSurfer derived measures of cortical thickness and surface area, even in scans that were rated as good quality. Our findings suggest that the inclusion of automated quality assessment measures can augment visual inspection and may find use as a covariate in analyses or to identify thresholds to exclude poor quality data.

Keywords: reconstruction; quality; quality assessment; automated quality; visual inspection

Journal Title: Human Brain Mapping
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.