BACKGROUND Six Sigma (6σ) is an efficient laboratory management method. We aimed to analyze the performance of immunology and protein analytes in terms of Six Sigma. METHODS Assays were evaluated… Click to show full abstract

BACKGROUND Six Sigma (6σ) is an efficient laboratory management method. We aimed to analyze the performance of immunology and protein analytes in terms of Six Sigma. METHODS Assays were evaluated for these 10 immunology and protein analytes: Immunoglobulin G (IgG), Immunoglobulin A (IgA), Immunoglobulin M (IgM), Complement 3 (C3), Complement 4 (C4), Prealbumin (PA), Rheumatoid factor (RF), Anti streptolysin O (ASO), C-reactive protein (CRP), and Cystatin C (Cys C). The Sigma values were evaluated based on bias, four different allowable total error (TEa) and coefficient of variation (CV) at QC materials levels 1 and 2 in 2020. Sigma Method Decision Charts were established. Improvement measures of analytes with poor performance were recommended according to the quality goal index (QGI), and appropriate quality control rules were given according to the Sigma values. RESULTS While using the TEaNCCL , 90% analytes had a world-class performance with σ>6, Cys C showed marginal performance with σ<4. While using minimum, desirable, and optimal biological variation of TEa, only three (IgG, IgM, and CRP), one (CRP), and one (CRP) analytes reached 6σ level, respectively. Based on σNCCL that is calculated from TEaNCCL , Sigma Method Decision Charts were constructed. For Cys C, five multi-rules (13s /22s /R4s /41s /6X , N = 6, R = 1, Batch length: 45) were adopted for QC management. The remaining analytes required only one QC rule (13s , N = 2, R = 1, Batch length: 1000). Cys C need to improve precision (QGI = 0.12). CONCLUSIONS The laboratories should choose appropriate TEa goals and make judicious use of Sigma metrics as a quality improvement tool.

Keywords: immunology protein; protein analytes; sigma; quality control; immunology

Journal Title: Journal of clinical laboratory analysis
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.