Isolated premature ventricular complexes (PVCs) are the most common arrhythmias observed in patients even if without structural heart disease.1 Although most PVCs originate from the right ventricular outflow tract (RVOT),… Click to show full abstract
Isolated premature ventricular complexes (PVCs) are the most common arrhythmias observed in patients even if without structural heart disease.1 Although most PVCs originate from the right ventricular outflow tract (RVOT), there are some PVCs that originate near the HIS bundle.2 The synthesized 18lead ECG consists of rightsided thoracic (V3R, V4R, V5R) and dorsal (V7, V8, V9) ECG leads derived from a mathematical calculation of the 12lead ECG, and the detailed mathematical formula is shown in Figure 1. The synthesized 18lead ECG has been reported to be effective for PVCs of an RVOT origin, but the rest remains to be elucidated.3 The aim of this study was to investigate the characteristics of the synthesized 18lead ECG in patients with PVCs originating from near the HIS bundle. The synthesized 18lead ECGs of 13 consecutive patients who underwent radiofrequency catheter ablation (RFCA) of idiopathic PVCs from near the HIS bundle at the Japan Community Healthcare Organization Osaka Hospital, Osaka General Medical Center, and Nara Prefectural Seiwa Medical Center from January 2018 to December 2020 were included in this retrospective analysis. The origin of the PVCs was identified by a cardiologist using a 3D mapping system (CARTO 3: Biosense Webster Inc or EnSite: Abbott Medical Inc). We analyzed the QRS morphology pattern of the synthesized 18lead ECG analyzed in those patients. This study was approved by the Ethics Committee of each hospital in accordance with the Declaration of Helsinki. The synthesized 18lead ECG and ECG characteristics in 13 patients with PVCs from near the HIS bundle are shown in Figure 2 and Table 1. The mean QRS duration of the ECG was 142.5 ± 26.9 ms. In 12 of 13 patients, a left bundle branch block pattern (92.3%) was present, and 11 of 13 patients had inferior axis deviation (84.6%). Regarding the rightsided chest leads of the synthesized 18lead ECG, in all patients, a QS pattern in lead V5R (100%) was observed, and in 12 of 13 patients, a QS pattern in leads V3R, V4R, and V5R (92.3%) was present. A comparison showed that the synthesized ECGs recorded during sinus rhythm and during PVCs were not consistent, as shown in Table 2. Several studies have shown that identifying PVCs originating from the vicinity of the ventricular septum remains complicated,4 and it is difficult to identify the origin of PVCs originating from near the HIS bundle based on the characteristics of the 12lead ECG. Noteworthy among our results was that there was a QS pattern in lead V5R in 100.0%. Igarashi et al reported that in the synthesized 18lead ECG recorded by pace mapping in the outflow tract, a QS pattern in lead V5R was observed in about 80% at the right coronary cusp (RCC), about 20% in the posterior RVOT, and nothing at the other sites.3 Combining the above study3 with our results, a QS pattern in lead V5R might have been specific to PVCs originating from near the HIS bundle and RCC. QRS morphology changes after RFCA are often observed in patients with idiopathic PVCs.5 In such cases, the use of the synthesized 18lead ECG's rightsided chest leads may assist in the remapping process. Regarding the mechanism of the QS pattern in lead V5R, in general the HIS bundle is anatomically closer to the RCC, and electrical conduction may propagate with a vector
               
Click one of the above tabs to view related content.