LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Computational modeling, fabrication and characterization of the deep eutectic solvent-based green molecular cage for selective metronidazole extraction from plasma followed by ultra-performance LC- diode array detector determination.

Photo from wikipedia

Four ternary deep eutectic solvents were computationally designed and synthesized, being used as candidate functional monomers in metronidazole molecular imprinting polymer synthesis, allowing selective extraction and determination by ultra-performance LC… Click to show full abstract

Four ternary deep eutectic solvents were computationally designed and synthesized, being used as candidate functional monomers in metronidazole molecular imprinting polymer synthesis, allowing selective extraction and determination by ultra-performance LC with diode array detector. In terms of metronidazole selective extraction, the best results were obtained by (deep eutectic solvent)2 :(ethylene glycol dimethacrylate)11 , in which deep eutectic solvent is the functional monomer constructed by combining three components in 6:6:2 ratios of choline chloride: ethylene glycol: methacrylic acid. The effects of different parameters on molecular imprinted solid-phase extraction of metronidazole were thoroughly explored through screening design and response surface methodology. The adsorption mechanism findings show that the adsorption data is primarily fitted on the Freundlich model based on higher correlation coefficient. Kinetic experiments have shown that the mechanism of adsorption fits the pseudo-second-order model. The best extraction recovery (96.5%) was obtained in 25-minute elution time, desorption temperature of 40°C, and 1.0 mL ACN as eluent. Metronidazole was measured by a validated ultra-performance LC diode array detection method. The calibration of the method was linear in the range of 0.1-10 μg/mL with LOD and LOQ of 0.03 and 0.1 μg/mL, respectively. The method was successfully applied for the determination of metronidazole in human plasma. This article is protected by copyright. All rights reserved.

Keywords: extraction; performance diode; ultra performance; diode array; deep eutectic; metronidazole

Journal Title: Journal of separation science
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.