LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Penalized maximum likelihood simultaneous longitudinal PET image reconstruction with difference‐image priors

Photo from wikipedia

Purpose Many clinical contexts require the acquisition of multiple positron emission tomography (PET) scans of a single subject, for example, to observe and quantitate changes in functional behaviour in tumors… Click to show full abstract

Purpose Many clinical contexts require the acquisition of multiple positron emission tomography (PET) scans of a single subject, for example, to observe and quantitate changes in functional behaviour in tumors after treatment in oncology. Typically, the datasets from each of these scans are reconstructed individually, without exploiting the similarities between them. We have recently shown that sharing information between longitudinal PET datasets by penalizing voxel‐wise differences during image reconstruction can improve reconstructed images by reducing background noise and increasing the contrast‐to‐noise ratio of high‐activity lesions. Here, we present two additional novel longitudinal difference‐image priors and evaluate their performance using two‐dimesional (2D) simulation studies and a three‐dimensional (3D) real dataset case study. Methods We have previously proposed a simultaneous difference‐image‐based penalized maximum likelihood (PML) longitudinal image reconstruction method that encourages sparse difference images (DS‐PML), and in this work we propose two further novel prior terms. The priors are designed to encourage longitudinal images with corresponding differences which have (a) low entropy (DE‐PML), and (b) high sparsity in their spatial gradients (DTV‐PML). These two new priors and the originally proposed longitudinal prior were applied to 2D‐simulated treatment response [18F]fluorodeoxyglucose (FDG) brain tumor datasets and compared to standard maximum likelihood expectation‐maximization (MLEM) reconstructions. These 2D simulation studies explored the effects of penalty strengths, tumor behaviour, and interscan coupling on reconstructed images. Finally, a real two‐scan longitudinal data series acquired from a head and neck cancer patient was reconstructed with the proposed methods and the results compared to standard reconstruction methods. Results Using any of the three priors with an appropriate penalty strength produced images with noise levels equivalent to those seen when using standard reconstructions with increased counts levels. In tumor regions, each method produces subtly different results in terms of preservation of tumor quantitation and reconstruction root mean‐squared error (RMSE). In particular, in the two‐scan simulations, the DE‐PML method produced tumor means in close agreement with MLEM reconstructions, while the DTV‐PML method produced the lowest errors due to noise reduction within the tumor. Across a range of tumor responses and different numbers of scans, similar results were observed, with DTV‐PML producing the lowest errors of the three priors and DE‐PML producing the lowest bias. Similar improvements were observed in the reconstructions of the real longitudinal datasets, although imperfect alignment of the two PET images resulted in additional changes in the difference image that affected the performance of the proposed methods. Conclusion Reconstruction of longitudinal datasets by penalizing difference images between pairs of scans from a data series allows for noise reduction in all reconstructed images. An appropriate choice of penalty term and penalty strength allows for this noise reduction to be achieved while maintaining reconstruction performance in regions of change, either in terms of quantitation of mean intensity via DE‐PML, or in terms of tumor RMSE via DTV‐PML. Overall, improving the image quality of longitudinal datasets via simultaneous reconstruction has the potential to improve upon currently used methods, allow dose reduction, or reduce scan time while maintaining image quality at current levels.

Keywords: reconstruction; image; pet; difference image; image reconstruction

Journal Title: Medical Physics
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.