LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

CT sinogram‐consistency learning for metal‐induced beam hardening correction

Photo by hajjidirir from unsplash

PURPOSE This paper proposes a sinogram-consistency learning method to deal with beam hardening-related artifacts in polychromatic computerized tomography (CT). The presence of highly attenuating materials in the scan field causes… Click to show full abstract

PURPOSE This paper proposes a sinogram-consistency learning method to deal with beam hardening-related artifacts in polychromatic computerized tomography (CT). The presence of highly attenuating materials in the scan field causes an inconsistent sinogram that does not match the range space of the Radon transform. When the mismatched data are entered into the range space during CT reconstruction, streaking and shading artifacts are generated owing to the inherent nature of the inverse Radon transform METHODS: The proposed learning method aims to repair inconsistent sinogram by removing the primary metal-induced beam hardening factors along the metal trace in the sinogram. Taking account of the fundamental difficulty in obtaining sufficient training data in a medical environment, the learning method is designed to use simulated training data and a patient's implant type-specific learning model is used to simplify the learning process. RESULTS The feasibility of the proposed method is investigated using a dataset, consisting of real CT scans of pelvises containing simulated hip prostheses. The anatomical areas in training and test data are different, in order to demonstrate that the proposed method extracts the beam hardening features, selectively. The results show that our method successfully corrects sinogram inconsistency by extracting beam hardening sources by means of deep learning. CONCLUSION This paper proposed a deep learning method of sinogram correction for beam hardening reduction in CT for the first time. Conventional methods for beam hardening reduction are based on regularizations, and have the fundamental drawback of being not easily able to use manifold CT images, while a deep learning approach has the potential to do so.

Keywords: beam hardening; sinogram consistency; learning method; consistency learning; beam

Journal Title: Medical Physics
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.