LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Self-powered nano-porous aerogel x-ray sensor employing fast electron current.

Photo from wikipedia

PURPOSE We developed a new class of aerogel-based thin-film self-powered radiation sensors employing high-energy electron current (HEC) in periodic multi-layer (high-Z | polyimide aerogel (PA) | low-Z) electrode microstructures. MATERIALS… Click to show full abstract

PURPOSE We developed a new class of aerogel-based thin-film self-powered radiation sensors employing high-energy electron current (HEC) in periodic multi-layer (high-Z | polyimide aerogel (PA) | low-Z) electrode microstructures. MATERIALS Low-Z (Al) and high-Z (Ta) electrodes were deposited on 50 μm-thick polyimide aerogel (PA) films to obtain sensors with Al-PA-Ta-PA-Al structures. Sensors were tested with X-rays in the 40-120 kVp range and with 2.5 MV, 6 MV and 6 MV-FFF linac beams (TrueBeam, Varian). Performance of PA-HEC sensors was compared to commercial A12 Farmer ionization chamber as well as to radiation transport simulations using CEPXS/ONEDANT with nanometer-to-micrometer spatial resolution. The computations included periodic and single-element structures N x (Al-PA-Ta-PA-Al) with variable layer thicknesses. RESULTS Signal from PA-HEC sensors was proportional to the simulated net leakage electron current (averaged over the PA thickness). Experimental response was linear with dose and independent of dose rate. Detector responses to different X-ray sources show higher signals for kVp photon energies, as expected, though a strong signal was obtained for MV energies as well. The signal scaled with total effective area inside the multi-elemental structures; e.g., the yield of a multi-element sensor made with 20 Ta layers compared to a single-element structure with 1 Ta layer of the same total thickness of Ta was 10 times greater for 6 MV beam and 23 times greater for 120 kVp. Beam attenuation per element in the detector was 0.5%, 1%, 3% and 46% respectively for 6 MV, 6 MV FFF, 2.5 MV and 120 kVp. CONCLUSION We demonstrated the feasibility of aerogel-based multilayer high-energy current (HEC) radiation detector and its application for flux/dose monitoring of kVp and radiotherapy MV beams with small beam attenuation. This article is protected by copyright. All rights reserved.

Keywords: aerogel; element; ray; self powered; electron current

Journal Title: Medical physics
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.