LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Statistical characterization of the linear attenuation coefficient in polychromatic CT scans.

Photo from wikipedia

PURPOSE To provide a unifying statistical model that characterizes the integrated X-ray intensity at the detector after logarithmic transformation and can be extended to the characterization of CT numbers in… Click to show full abstract

PURPOSE To provide a unifying statistical model that characterizes the integrated X-ray intensity at the detector after logarithmic transformation and can be extended to the characterization of CT numbers in the reconstructed image. METHODS We study the statistical characteristics of polyenergetic X-ray beams in the detector. Firstly, we consider the characterization of the integrated X-ray intensity at the detector through a probabilistic model (Compound Poisson) that describes its statistics. We analyze its properties and derive the probabilistic distribution after the logarithmic transformation analytically. Finally, we propose a more tractable probabilistic distribution with the same features observed in the characterization, the non-central Gamma. This distribution exhibits desirable properties for the statistical characterization across the reconstruction process. We assess the assumptions adopted in the derivation of the statistical models throughout Monte Carlo simulations and validate them with a water phantom and a lung phantom acquired in a Siemens clinical CT scan. We evaluate the statistical similarities between the theoretical distribution and the non-central Gamma using a power analysis with a Kolmogorov-Smirnov test for a 95% confidence level. RESULTS The Kolmogorov-Smirnov goodness of fit test obtained for the Monte Carlo simulation shows an extremely high agreement between the empirical distribution of the post-logarithmic integrated X-ray intensity and the non-central Gamma. The experimental validation performed with both phantoms confirmed the excellent match between the theoretical distribution, the proposed non-central Gamma, and sample distributions in all situations. CONCLUSION We derive an analytical model describing the post-log distribution of the linear attenuation coefficient in the sensor for polychromatic CT scans. We also demonstrate that the non-central Gamma distribution approximates well the theoretical distribution. This distribution also approximates well the CT numbers after reconstruction since it naturally extends across linear operations involved in filtered backprojection reconstructions. This probabilistic model may provide the analytical foundation to define new likelihood-based reconstruction methodologies for polychromatic scans.

Keywords: central gamma; polychromatic scans; non central; characterization; distribution

Journal Title: Medical physics
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.