Imaging of polarized components of Cerenkov-light and luminescence of water during carbon ion irradiation.

Photo from wikipedia

PURPOSE The luminescence image of water during the irradiation of carbon ions showed higher intensity at shallow depths than dose distribution due to the contamination of Cerenkov-light from secondary electrons.… Click to show full abstract

PURPOSE The luminescence image of water during the irradiation of carbon ions showed higher intensity at shallow depths than dose distribution due to the contamination of Cerenkov-light from secondary electrons. Since Cerenkov-light is coherent and polarized for the light produced during the irradiation of carbon ions to water, the reduction of Cerenkov-light may be possible with a polarizer. In addition, there is no information on the polarization of the luminescence of water. To clarify these points, we measured the optical images of water during the irradiation of carbon ions with a polarizer by changing the directions of the transmission axis. METHODS Imaging was conducted using a cooled charge-coupled device (CCD) camera during the irradiation of 241.5 MeV/n energy carbon ions to a water phantom with a polarizer in front of the lens by changing the transmission axis parallel and perpendicular to the carbon-ion beam. RESULTS With the polarizer parallel to the carbon-ion beam, the intensity at the shallow depth was ~26 % higher than that measured with the polarizer perpendicular to the beam. We found no significant intensity difference between these two images at deeper depths where the Cerenkov-light was not included. The difference image of the parallel and perpendicular directions showed almost the same image as the simulated Cerenkov-light distribution. Using the measured difference image, correction of the Cerenkov component was possible from the measured luminescence image of water during the irradiation of carbon ions. CONCLUSION We could measure the difference of the Cerenkov-light component by changing the transmission axis of the polarizer. Also we clarified that there was no difference in the luminescence of water by changing the transmission axis of the polarizer.

Keywords: irradiation; carbon ions; carbon; water; cerenkov light; luminescence

Journal Title: Medical physics
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.