Technical note: Validation of 3D ultrasound for image registration during oncological liver surgery.

Photo from wikipedia

PURPOSE Registration of pre- and intraoperative images is a crucial step of surgical liver navigation, where rigid registration of vessel centerlines is currently commonly used. When using 3D ultrasound (US),… Click to show full abstract

PURPOSE Registration of pre- and intraoperative images is a crucial step of surgical liver navigation, where rigid registration of vessel centerlines is currently commonly used. When using 3D ultrasound (US), accuracy during navigation might be influenced by the size of the intraoperative US volume, yet the relationship between registration accuracy and US volume size is understudied. In this study, we specify an optimal 3D US volume size for registration using varying volumes of liver vasculature. While previous studies measured accuracy at registered fiducials, in this work, accuracy is determined at the target lesion which is clinically the most relevant structure. METHODS 3D US volumes were acquired in 14 patients after laparotomy and liver mobilization. Manual segmentation of vasculature and centerline extraction was performed. Intraoperative and preoperative vasculature centerlines were registered with coherent point drift, using different subvolumes (sphere with radius r = 30, 40, …, 120 mm). Accuracy was measured by fiducial registration error (FRE) between vessel centerlines and target registration error (TRE) at the center of the target lesion. RESULTS The lowest FRE for vessel registration was reached with r = 50 mm (6.5 ± 2.5 mm), the highest with r = 120 mm (7.1 ± 2.1 mm). Clinical accuracy at the target lesion, resulted most accurate (TRE = 8.8 ± 5.0 mm) in subvolumes with a radius of 50 mm. Smaller ultrasound subvolumes resulted in lower average TREs when compared to larger ultrasound subvolumes (Pearson's correlation coefficient R = 0.91, p < 0.001). CONCLUSION Our results indicate that there is a linear correlation between ultrasound volume size and registration accuracy at the tumor. Volumes with radii of 50 mm around the target lesion yield higher accuracy (p < 0.05).

Keywords: target lesion; accuracy; liver; size; registration

Journal Title: Medical physics
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.