Inferior alveolar canal segmentation based on cone-beam computed tomography.

Photo from wikipedia

PURPOSE The shape and position of the inferior alveolar canal (IAC) are analyzed to effectively reduce the risk of iatrogenic injury based on cone-beam computer tomography (CBCT). To assist dental… Click to show full abstract

PURPOSE The shape and position of the inferior alveolar canal (IAC) are analyzed to effectively reduce the risk of iatrogenic injury based on cone-beam computer tomography (CBCT). To assist dental clinicians to make better use of the IAC information, we propose an IAC segmentation method based on CBCT images. METHODS In this paper, CBCT images are firstly preprocessed by the Hounsfield unit values clipping and gray normalization. Secondly, based on the multi-plane reconstruction (MPR) and curved surface reconstruction, the curved MPR image sets are generated by the smooth dental arch curve with a sampling distance of 1.00 pixels. Then, the K-means clustering algorithm is used to cluster the texture parameters of the gray level-gradient co-occurrence matrix (GGCM) enhanced by the gradient directions to improve the image contrast of the IAC. Finally, the IAC edges are roughly segmented by the 2D line-tracking method, and smoothed by the fourth-order polynomial to obtain the final segmentation result. RESULTS 21 real clinical dental CBCT datasets were used to test the proposed method. The manual segmentation results of two pecialized dental clinicians were used as quantitative evaluation criteria. The dice similarity index (DSI), average symmetric surface distance (ASSD), and mean curve distance (MCD) of the left IAC are 0.93 (SD = 0.01), 0.16 mm (SD = 0.05 mm), and 1.59 mm (SD = 0.25 mm), respectively; the DSI, ASSD, and MCD of the right IAC are 0.93 (SD = 0.02), 0.16 mm (SD = 0.05 mm), and 1.60 mm (SD = 0.30 mm), respectively. CONCLUSIONS The proposed method provides an effective image enhancement and segmentation solution to analyze the shape and position of the IAC. Experimental results show that the relationships between the IAC and other structures can be accurately reflected in the panoramic images without superimposition and geometric distortion, and the smooth edges of the IAC can be segmented. This article is protected by copyright. All rights reserved.

Keywords: based cone; segmentation; alveolar canal; inferior alveolar; cone beam

Journal Title: Medical physics
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.