LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Head CT dose reduction with organ-based tube current modulation.

Photo from wikipedia

BACKGROUND A helical head CT examination uses a pitch factor (PF) of < 1.0, resulting in a part of the slice being directly irradiated twice. This raises the possibility of… Click to show full abstract

BACKGROUND A helical head CT examination uses a pitch factor (PF) of < 1.0, resulting in a part of the slice being directly irradiated twice. This raises the possibility of double irradiation, which may increase the amount of radiation to the lens. Organ-based tube current modulation (OBTCM) is an effective method for reducing lens exposure because it reduces the dose to the anterior aspect of the patient. However, it is challenging to visualize the complex dose distribution when factoring in double irradiation. PURPOSE To visualize twice-irradiated areas in helical head CT in three dimensions and to clarify the exposure reduction effect of OBTCM. MATERIAL AND METHODS A leuco crystal violet (LCV) dosimeter was placed into an empty polyethylene terephthalate bottle 16.5 cm in diameter. Helical scans were performed without and with OBTCM using the following parameters: tube voltage 120 kV, tube current 600 mA, pitch factor 0.637, rotation time 0.5 s, 80 (detector rows) × 0.5 mm (detector collimation), and ten scans. Exposed areas were visualized using an optical computed tomography (OCT) system designed by our group. The dose reduction rate of OBTCM was defined as the ratio of the average values of the histogram with the dose value on the x-axis and the frequency on the y-axis without and with OBTCM at 90° to the anterior midline. RESULTS The LCV dosimeter visualized the spiral-shaped twice-irradiated areas. Double irradiation resulted in a dose of 2.19/1.90 Gy and 1.38/1.19 Gy (15.0% and 15.9% increase) without and with OBTCM, respectively. The dose reduction using OBTCM was 29.6% at 90° anterolateral. CONCLUSION The LCV dosimeter visualized the complex three-dimensional irradiated areas and enabled dose measurement in twice-irradiated areas. Increased exposure from double irradiation was attenuated by OBTCM. This article is protected by copyright. All rights reserved.

Keywords: double irradiation; tube current; dose reduction; based tube; organ based; reduction

Journal Title: Medical physics
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.