Feasibility of Isodose-shaped scintillation detectors for the measurement of gamma Knife® output factors.

PURPOSE Scintillation detectors were 3D printed based on a gamma knife (GK) dose distribution to calculate the volume averaging effect. The collimator output factors were measured using isodose-shaped scintillators (ISSs)… Click to show full abstract

PURPOSE Scintillation detectors were 3D printed based on a gamma knife (GK) dose distribution to calculate the volume averaging effect. The collimator output factors were measured using isodose-shaped scintillators (ISSs) and compared with those of a micro-diamond detector and previous reports. METHODS An absorbed dose distribution in a spherical dosimetry phantom with a radius of 8 cm was obtained from GK treatment planning software (Leksell GammaPlan (LGP), Elekta AB, Stockholm, Sweden). Two types of ISSs were fabricated to fit the 97.2% (ISS-1) and 95.6% (ISS-2) isodose surfaces. The volume averaging correction factors were obtained by dividing the absorbed dose to water in the central voxel (CV) by that in the ISS. The correction effect due to the difference between the ISS and water was calculated by Monte Carlo simulations. Ten ISS detectors, five of each type, were used to measure the output factors of the 4 and 8 mm collimators of a GK IconTM to assess system consistency. The output factors of seven GKs were measured using two ISS detectors, one of each type, and a PTW T60019 (PTW, Freiburg, Germany) micro-diamond detector. RESULTS The detector output ratios (DORs) measured using the five ISSs of each type were consistent, with standard uncertainties less than 0.2%. In the 4 mm field, the volume averaging correction factor ratios were 1.018 and 1.026, and the output factors after all corrections were 0.827 (0.006) and 0.825 (0.006) for ISS-1 and ISS-2, respectively. In the 8 mm field, the volume averaging correction factor ratios were 1.000 for both ISS types, and the output factors were 0.898 (0.003) and 0.900 (0.003) for ISS-1 and ISS-2, respectively. The ISS detectors could measure the output factors of a GK with uncertainties comparable to that of the PTW 60019 detector. The output factors of all detectors decreased with the dose rate. CONCLUSION The volume averaging effect of an ISS developed in-house could be calculated using known dose distributions. The collimator output factors of the GK Perfexion/Icon™ models measured using ISS detectors were consistent with those of a commercial synthetic micro-diamond detector and recent studies. This article is protected by copyright. All rights reserved.

Keywords: scintillation detectors; output; detector; output factors; volume averaging

Journal Title: Medical physics
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.