Technical note: Design and initial evaluation of a novel physical breast phantom to monitor image quality in digital breast tomosynthesis.

Photo from wikipedia

PURPOSE To describe the creation process of a new breast phantom specifically designed to monitor quality control (QC) metrics consistency over several months in digital breast tomosynthesis (DBT). METHODS The… Click to show full abstract

PURPOSE To describe the creation process of a new breast phantom specifically designed to monitor quality control (QC) metrics consistency over several months in digital breast tomosynthesis (DBT). METHODS The semi-anthropomorphic Tomomam® phantom was designed and evaluated twice monthly on a single Hologic Selenia Dimensions® unit over five months. The phantom is manufactured in a one-piece epoxy resin homogeneous material as the basis for manufacturing, simulating breast tissue as 50% equivalent glandular/50% equivalent adipose and compressed thickness of 60 mm. The distribution of test-objects on different planes inside the phantom should allow the quantification of ten image quality metrics: reproducibility, signal difference-to-noise ratio (SDNR), geometric distortions in the plane, missing or added tissue at chest wall, at the top and bottom of images stack and lateral sides, in-plane homogeneity, image scoring, artifact spread function (ASF), geometric distortions in the volume. SDNR was quantified according to glandular (GL) and adipose (AD) tissues. Tolerance criteria per parameter were described to analyze results over the study time. RESULTS Mean scores were equal to 15.4, 15.0 and 11.6 for masses, microcalcifications and fibers, respectively. A large difference between GL and AD tissues for SDNR metrics was noted over the study time: the best results were obtained from GL tissues. Both geometric distortions and local homogeneity in the plane conformed to expected values. The mean volume value of the triangular prism was 11.3 % greater than the expected value due to a reconstruction height equal to 66 mm instead of 60 mm. CONCLUSIONS In this study, we monitored several QC metrics discriminating glandular and adipose tissues by using a new breast phantom developed by us. The preliminary clinical tests demonstrated that the Tomomam® phantom could be used to reliably and efficiently track ten quality control metrics with a single acquisition. More data need to be acquired to refine tolerance criteria for some metrics.  This article is protected by copyright. All rights reserved.

Keywords: quality; breast; digital breast; breast phantom; phantom; image

Journal Title: Medical physics
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.