Energy layer optimization via energy matrix regularization for proton spot-scanning arc therapy.

Photo from wikipedia

PURPOSE Spot-scanning arc therapy (SPArc) is an emerging proton modality that can potentially offer a combination of advantages in plan quality and delivery efficiency, compared to traditional IMPT of a… Click to show full abstract

PURPOSE Spot-scanning arc therapy (SPArc) is an emerging proton modality that can potentially offer a combination of advantages in plan quality and delivery efficiency, compared to traditional IMPT of a few beam angles. Unlike IMPT, frequent low-to-high energy layer switching (so called switch-up (SU)) can degrade delivery efficiency for SPArc. However, it is a tradeoff between the minimization of SU times and the optimization of plan quality. This work will consider the energy layer optimization (ELO) problem for SPArc and develop a new ELO method via energy matrix (EM) regularization to improve plan quality and delivery efficiency. METHODS The major innovation of EM method for ELO is to design an energy matrix that encourages desirable energy-layer map with minimal SU during SPArc, and then incorporate this energy matrix into the SPArc treatment planning to simultaneously minimize the number of SU and optimize plan quality. The EM method is solved by the fast iterative shrinkage-thresholding algorithm and validated in comparison with a state-of-the-art method, so-called energy sequencing (ES). RESULTS EM is validated and compared with ES using representative clinical cases. In terms of delivery efficiency, EM had fewer SU than ES with an average of 35% reduction of SU. In terms of plan quality, compared to ES, EM had smaller optimization objective values and better target dose conformality, and generally lower dose to organs-at-risk and lower integral dose to body. In terms of computational efficiency, EM was substantially more efficient than ES by at least ten-fold. CONCLUSION We have developed a new ELO method for SPArc using energy matrix regularization, and shown that this new method EM can improve both delivery efficiency and plan quality, with substantially reduced computational time, compared to ES. This article is protected by copyright. All rights reserved.

Keywords: plan quality; energy; energy layer; efficiency; energy matrix

Journal Title: Medical physics
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.