LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Technical Note: A method for generating lesion-specific non-uniform rotational margins for targets remote from isocenter.

Photo by heftiba from unsplash

PURPOSE To present a novel method for generating non-uniform lesion-specific rotational margins for targets remote from isocenter, as encountered in single isocenter multiple metastasis radiotherapy (SIMMRT). METHODS Target contours are… Click to show full abstract

PURPOSE To present a novel method for generating non-uniform lesion-specific rotational margins for targets remote from isocenter, as encountered in single isocenter multiple metastasis radiotherapy (SIMMRT). METHODS Target contours are rotated using a large series of 3D rotations, corresponding to a given range of rotational uncertainty, and combined to create a rotational envelope that encompasses potential motion. A set of artificial spherical targets ranging from 0.5 - 2.0 cm in diameter, and residing a distance of 1 - 15 cm from isocenter, are used to generate rotational envelopes assuming uncertainties of 0.5 - 3.0°. Computing time and number of samples are reported for simulated scenarios. Hausdorff distances (HD) between rotational envelopes and original target structures are calculated to represent the magnitude of uniform expansion required to encompass potential rotation. Volume differences between uniform expansions (based on HD) and rotational envelopes are reported to articulate potential advantages. RESULTS Median time to generate rotational envelopes was 60 seconds (31 - 974 seconds). Median required samples was 86 (61 - 851). Maximum HD for all targets located 10 cm from isocenter was 1.5 mm, 3.0 mm, 5.8 mm, and 8.6 mm assuming 0.5°, 1.0°, 2.0°, and 3.0° of rotational uncertainty respectively. At 5 cm from isocenter, and assuming 0.5° of rotational uncertainty, volumes were decreased by 0.07 cc (60%), 0.24 cc (39%), and 1.08 cc (19%) for 5 mm, 10 mm, and 20 mm targets respectively. At 10 cm from isocenter and 1.0° of uncertainty, volumes decreased by 0.42 cc (58%), 2.0 cc (40%), and 2.5 cc (27%). On average target volumes decreased 45% (SD = 17%) when compared with uniform expansions based on HD. CONCLUSION Rotational margins may be generated by sampling a set of 3D rotations. Resulting margins explicitly account for target shape, distance from isocenter, and magnitude of rotational uncertainty, while reducing treated volumes when compared with uniform expansions. This article is protected by copyright. All rights reserved.

Keywords: rotational margins; uncertainty; isocenter; lesion specific; method generating; non uniform

Journal Title: Medical physics
Year Published: 2022

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.