BACKGROUND With the introduction of prostate specific membrane antigen (PSMA) PET/CT, the detection rate of prostate cancer metastases has improved significantly, both for primary staging and for biochemical recurrence. EANM/SNMMI… Click to show full abstract
BACKGROUND With the introduction of prostate specific membrane antigen (PSMA) PET/CT, the detection rate of prostate cancer metastases has improved significantly, both for primary staging and for biochemical recurrence. EANM/SNMMI guidelines recommend a 60 min time interval between [68 Ga]Ga-PSMA administration and acquisition. PURPOSE This study evaluates the possibility of a shorter time interval by investigating the dynamic change in image quality measures. METHOD We retrospectively analyzed 10 consecutive prostate cancer patients who underwent a dynamic whole body [68 Ga]Ga-PSMA-11 PET/CT of 75 min from skull vertex to mid-thigh using Siemens FlowMotion. PET images were acquired directly after injection of 1.5 MBq/kg [68 Ga]Ga-PSMA-11. Image quality measures included lesion maximum standardized uptake value corrected for lean body mass (SULmax ), tumor-to-background ratio (TBR), and contrast-to-noise ratio (CNR). Quantitative analysis of image quality in dynamic PET was performed using PMOD (version 4.2). Regions of interest (ROIs), drawn included different types of prostate lesions (primary tumor, lymph nodes, and bone metastasis), organ tissue (liver, spleen, lacrimal gland, submandibular gland, parotid gland, urinary bladder, kidneys blood pool [ascending aorta], left ventricle), bone tissue (4th lumbar vertebral body [L4]) and muscle tissue (gluteus maximus). To further investigate image quality four 10 min multi-frame reconstructions with clinical parameters were made at different post-injection times (15, 30, 45, and 60 min). A nuclear medicine physician performed a blinded lesion detectability evaluation on these multi-frame reconstructions for different prostate cancer lesions. RESULTS Six primary prostate tumors in seven patients with prostate in situ, 13 lymph node metastases in six patients and up to 12 bone metastases in three patients were found. The different prostate lesion types (lymph nodes metastases, bone metastases, and primary prostate tumor) all show an increase in average SULmax , TBR, and CNR over time during the scan. The normalized average SULmax , TBR, and CNR of the combined prostate lesions at 15, 30, and 45 min post-injection scans were all significant p < 0.05 lower from the 60 min post-injection [68 Ga]Ga-PSMA-11 PET/CT (9.5 ± 4.5, 12.7 ± 6.2, and 41.8 ± 24.5, respectively). At patient level, the reader concluded the same regarding the presence/absence of primary prostate cancer recurrence, lymph node metastases, and/or bone metastases on all <60 min post-injection [68 Ga]Ga-PSMA-11 PET/CT's in comparison to the reference scan (60 min post-injection). At lesion level, all bone metastases seen on the reference scan were also seen on all <60 min post-injection [68 Ga]Ga-PSMA-11 PET/CT's but there were some lymph nodes (n = 2) metastases missed on the 15, 30, and 45 min post-injection scans. One lymph node metastasis on both the 15 and 30 min post-injection [68 Ga]Ga-PSMA-11 PET/CT's was missed and one lymph node metastasis was missed, only on the 45 min post-injection [68 Ga]Ga-PSMA-11 PET/CT. CONCLUSION Shorter post-injection times (15, 30, and 45 min) compared to the recommended post-injection time of 60 min are not optimal. However, the impact of a shorter time interval of 45 min instead of 60 min between [68 Ga]Ga-PSMA-11 administration and the start of PET/CT acquisition on both image quality (SULmax , TBR, and CNR) and lesion detection, while significant, is small.
               
Click one of the above tabs to view related content.