LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Morphometric Analysis of the Lumbar Vertebrae Concerning the Optimal Screw Selection for Transpedicular Stabilization.

Photo by ammar_elattar1 from unsplash

Transpedicular stabilization is a frequently used spinal surgery for fractures, degenerative changes, or neoplastic processes. Improper screw fixation may cause substantial vascular or neurological complications. This study seeks to define… Click to show full abstract

Transpedicular stabilization is a frequently used spinal surgery for fractures, degenerative changes, or neoplastic processes. Improper screw fixation may cause substantial vascular or neurological complications. This study seeks to define detailed morphometric measurements of the pedicle (height, width, and surface area) in the aspects of screw length and girth selection and the trajectory of its implantation, i.e., sagittal and transverse angle of placement. The study was based on CT examinations of 100 Caucasian patients (51 women and 49 men) aged 27-75 with no anatomical, degenerative, or post-traumatic spine changes. The results were stratified by gender and body side, and they were counter compared with the available literature database. Pedicle height decreased from L1 to L4, ranging from 15.9 to 13.3 mm. Pedicle width increased from L1 to L5, extending from 6.1 to 13.2 mm. Pedicle surface area increased from L1 to L5, ranging from 63 to 140 mm2. Distance from the point of entry into the pedicle to the anterior surface of the vertebral body, defining the maximum length of a transpedicular screw, varied from 54.0 to 50.2 mm. Variations concerning body sides were inappreciable. A transverse angle of screw trajectory extended from 20° to 32°, shifting caudally from L1 to L5, with statistical differences in the L3-L5 segments. A sagittal angle varied from 10° to 12°, without such definite relations. We conclude that the L1 and L2 segments display the most distinct morphometric similarities, while the greatest differences, in both genders, are noted for L3, L4, and L5. The findings enable the recommendation of the following screw diameters: 4 mm for L1-L2, 5 mm for L3, 6 mm for L4-L5, and the length of 50 mm. We believe the study has extended clinical knowledge on lumbar spine morphometry, essential in the training physicians engaged in transpedicular stabilization.

Keywords: transpedicular stabilization; stabilization; pedicle; morphometric analysis; selection; lumbar

Journal Title: Advances in experimental medicine and biology
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.