5-Hydroxymethylcytosine (5hmC) is an abundant DNA modification in human and mouse brain, as well as in embryonic stem cells, while severely depleted in multiple types of cancer. Assays for 5hmC… Click to show full abstract
5-Hydroxymethylcytosine (5hmC) is an abundant DNA modification in human and mouse brain, as well as in embryonic stem cells, while severely depleted in multiple types of cancer. Assays for 5hmC detection and quantification, both on a locus-specific and global level, are limited in number and often resource-intensive. Immunodetection of 5hmC through antibodies remains a cost-effective and widely accessible approach. This chapter describes an ELISA-based protocol for 5hmC detection and quantification in genomic or in vitro modified DNA. It is based on the passive adsorption of DNA onto a solid polystyrene surface and the specific detection of 5hmC, which generates a measurable chemiluminescent signal, proportional to the amount of immobilized 5hmC. The assay utilizes a standard curve for interpolation of 5hmC percentage and a loading standard for monitoring loading precision.
               