LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Fully threaded headless compression screw versus partially threaded cancellous lag screw in medial malleolus fractures: clinical and radiological outcomes

Photo by nappystudio from unsplash

Purpose The aim of this study was to evaluate the clinical and radiological results of medial malleolar fractures, which were treated with fully threaded headless compression screws and to compare… Click to show full abstract

Purpose The aim of this study was to evaluate the clinical and radiological results of medial malleolar fractures, which were treated with fully threaded headless compression screws and to compare the clinical and radiological results of this screws and partially threaded cancellous lag screws. Methods Sixty-one patients who attended the final follow-up examination were included in the study. Group 1 comprised 29 patients applied with fully threaded headless compression screws and Group 2 comprised 32 patients with partially threaded cancellous lag screws. Radiological evaluation was made with standard radiographs. The clinical evaluations were applied using the AOFAS ankle hindfoot scale. Pain or sensitivity by touching over the medial malleolus was recorded and scored according to Visual Analog Scale. Results No significant differences were determined between the groups with respect to age, gender, fracture type, follow-up time, bone union time and AOFAS scores. The medial sensitivity associated with implant irritation was significantly lower in Group 1. There was no need for removal of the fixation material in any patient of Group 1. Conclusions The results of this study showed satisfactory results in the two fixation techniques in medial malleolar fractures. However, the rates of medial sensitivity associated with implant irritation were lower in the group where fully threaded headless compression screws were used. Therefore, to prevent postoperative patient dissatisfaction caused by persistent medial sensitivity associated with implant irritation, despite successful surgical treatment, the primary choice may be fully threaded headless compression screws.

Keywords: headless compression; clinical radiological; fully threaded; threaded headless; partially threaded

Journal Title: European Journal of Trauma and Emergency Surgery
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.