LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Low rates of serious complications but high rates of hardware removal after high tibial osteotomy with Tomofix locking plate

Photo by framesforyourheart from unsplash

The purpose of this study was to analyse adverse events encountered in medial opening wedge high tibial osteotomy (MOWHTO) utilizing contemporary surgical techniques with the Tomofix locking plate (DePuy Synthes,… Click to show full abstract

The purpose of this study was to analyse adverse events encountered in medial opening wedge high tibial osteotomy (MOWHTO) utilizing contemporary surgical techniques with the Tomofix locking plate (DePuy Synthes, Raynham, MA, USA) and categorize them by their severity and need for further medical/surgical management. It was hypothesized that there would be low rates of serious complications after medial opening wedge high tibial osteotomy utilizing an internal locking plate fixator. This study included 169 consecutive patients (200 knees) who underwent MOWHTO with a Tomofix locking plate at a single center, completing a minimum 2-year follow-up. Types of intra- and post-operative adverse events were retrospectively identified by an independent observer and categorized by their severity and further need of management. Additional surgery due to elective hardware removal was not included in the adverse event classification. There were in total 58 (29%) adverse events, the majority (13.5%) of which required no additional treatment (class 1). Class 1 events included lateral cortex hinge fractures that were observed in 8.5% (17 knees) and delayed wound healing 2% (4/200). Adverse events requiring additional or extended nonoperative management (class 2) were 9%. These included post-operative stiffness in 1% (2/200), low grade infection in 1.5% (3/200), delayed union in 5.4% (11/200), deep vein thrombosis 0.5% (1/200). One hundred and four knees (52%) underwent elective hardware removal. Serious adverse events requiring unplanned additional or revision surgery and/or long-term medical care (class 3) were the least reported (6.5%). Aseptic non-union was reported in 2.5%, deep infection requiring revision in 2% and limited hardware failure 1%. A low rate of serious complications (6.5%) requiring unplanned additional surgery (class 3) was found. The overall rate of complications following MOWHTO with Tomofix locking plate was 29% and the majority (13.5%) required no additional treatment (class 1). Lateral hinge fractures were the most common complication (8.5%) and these were associated with corrections over 12 mm. However, 52% knees required a further operation for elective hardware removal. Level IV, prospective study without control group.

Keywords: high tibial; hardware removal; class; tomofix locking; adverse events; locking plate

Journal Title: Knee Surgery, Sports Traumatology, Arthroscopy
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.