LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Prior iterative reconstruction (PIR) to lower radiation dose and preserve radiologist performance for multiphase liver CT: a multi-reader pilot study

Photo by towfiqu999999 from unsplash

Purpose Prior iterative reconstruction (PIR) spatially registers CT image data from multiple phases of enhancement to reduce image noise. We evaluated PIR in contrast-enhanced multiphase liver CT. Methods Patients with… Click to show full abstract

Purpose Prior iterative reconstruction (PIR) spatially registers CT image data from multiple phases of enhancement to reduce image noise. We evaluated PIR in contrast-enhanced multiphase liver CT. Methods Patients with archived projection CT data with proven malignant or benign liver lesions, or without lesions, by reference criteria were included. Lower-dose PIR images were reconstructed using validated noise insertion from multiphase CT exams (50% dose in 2 phases, 25% dose in 1 phase). The phase of enhancement most relevant to the diagnostic task was selected for evaluation. Four radiologists reviewed routine-dose and lower-dose PIR images, circumscribing liver lesions and rating confidence for malignancy (0 to 100) and image quality. JAFROC Figures of Merit (FOM) were calculated. Results 31 patients had 60 liver lesions (28 primary hepatic malignancies, 6 hepatic metastases, 26 benign lesions). Pooled JAFROC FOM for malignancy for routine-dose CT was 0.615 (95% CI 0.464, 0.767) compared to 0.662 for PIR (95% CI 0.527, 0.797). The estimated FOM difference between the routine-dose and lower-dose PIR images was + 0.047 (95% CI − 0.023, + 0.116). Pooled sensitivity/specificity for routine-dose images was 70%/68% compared to 73%/66% for lower-dose PIR. Lower-dose PIR had lower diagnostic image quality (mean 3.8 vs. 4.2, p  = 0.0009) and sharpness (mean 2.3 vs. 2.0, p  = 0.0071). Conclusions PIR is a promising method to reduce radiation dose for multiphase abdominal CT, preserving observer performance despite small reductions in image quality. Further work is warranted.

Keywords: dose pir; pir; pir lower; dose; multiphase; lower dose

Journal Title: Abdominal Radiology
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.