LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

High incidence of complications associated with shoulder girdle reconstruction utilizing a Stryker proximal humerus cap endoprosthesis following Tikhoff-Linberg resections

Photo by kilyan_s from unsplash

Introduction The Tikhoff-Linberg procedure is a limb salvage technique for tumours of the shoulder girdle which preserves function of the hand and elbow; however, shoulder function is limited. A humeral… Click to show full abstract

Introduction The Tikhoff-Linberg procedure is a limb salvage technique for tumours of the shoulder girdle which preserves function of the hand and elbow; however, shoulder function is limited. A humeral cap endoprosthesis (Stryker Orthopedics, Mahwah, NJ, USA) was developed within the Modular Replacement System (MRS) to act as a functional spacer for these defects; however, the outcomes of this implant have not been described. Methods Thirty-three (17 male, 16 female) patients underwent a Tikhoff-Linberg procedure at our institution. Of these, 17 (11 females, 6 males) were reconstructed with a MRS humerus endoprosthesis. Outcomes and complications were compared between patients who were reconstructed ( n  = 17) and those who were not ( n  = 16). Results Complications occurred in 14 (42%) patients, with more complications in patients who were reconstructed ( n  = 11, 65% vs. n  = 3, 19%, p  = 0.01). Endoprosthetic complications included stress shielding of the bone/prosthesis interface ( n  = 7, 41%) and subluxation/instability ( n  = 5, 29%), leading to a revision surgery in two (12%). Post-operatively, the mean Musculoskeletal Tumor Society Score (MSTS93) was 67 ± 11%, with no difference in the mean MSTS93 between patients who were reconstructed and those who were not (67 ± 10% vs. 68 ± 12%, p  = 0.77). Conclusions Reconstruction with a MRS humerus cap endoprosthesis resulted in a high rate of complications following a Tikhoff-Linberg procedure. Stress shielding and subluxation were common, and as such, the use of this prosthesis is limited to cases where a standard implant is not a feasible option.

Keywords: endoprosthesis; humerus; cap endoprosthesis; tikhoff linberg

Journal Title: International Orthopaedics
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.