LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

In Vitro Quantification of Luminal Denudation After Crimping and Balloon Dilatation of Endothelialized Covered Stents

Photo by amyshamblen from unsplash

PurposeCovered stents have been demonstrated to reduce restenosis; however, the membrane’s limited biocompatibility can still lead to thrombus formation. To obtain optimal surface hemocompatibility, endothelialization of the luminal surface has… Click to show full abstract

PurposeCovered stents have been demonstrated to reduce restenosis; however, the membrane’s limited biocompatibility can still lead to thrombus formation. To obtain optimal surface hemocompatibility, endothelialization of the luminal surface has been proposed. However, the effect of delivery procedures, such as crimping and balloon dilatation, on the endothelial layer has not been quantified. This study investigated the impact of such procedures on endothelialized covered stents in vitro.MethodsUsing an injection molding technique, bare metal stents were covered with fibrin subsequently, endothelialized and conditioned in a bioreactor under arterial pressure (80–120 mmHg) and shear stress (1 Pa). For each set of experiments, three covered stents were prepared, one being subjected to crimping alone, one to crimping followed by balloon dilatation and one serving as control. The experiment was repeated three times. The endothelial coverage was quantified by scanning electron microscopy (SEM). The functionality of the endothelium after exposure to platelet-rich plasma was evaluated by immunohistochemistry and SEM.ResultsThe mean endothelial coverage of control, crimped, crimped and balloon-dilated stents was 87.6, 80.1 and 52.1%, respectively, indicating that endothelial cells detached significantly not after crimping (P = 0.465) but following balloon dilatation (P < 0.001). The cells present on the stent’s surface, either after crimping or crimping followed by balloon dilatation, expressed eNOS and CD31 and exhibited no platelet adhesion.ConclusionThe simulated delivery procedure resulted in the retention of viable cells on more than half of the luminal surface. The main damage to the layer occurred during balloon dilatation.

Keywords: balloon dilatation; crimping balloon; endothelialized covered; covered stents; balloon

Journal Title: CardioVascular and Interventional Radiology
Year Published: 2017

Link to full text (if available)