LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Microwave Ablation of the Lung in a Porcine Model: Vessel Diameter Predicts Pulmonary Artery Occlusion

Photo from wikipedia

PurposeTo determine the size of pulmonary artery (PA) at risk for occlusion during percutaneous microwave ablation and to assess the effect of vessel diameter, number, and patency, on ablation zone… Click to show full abstract

PurposeTo determine the size of pulmonary artery (PA) at risk for occlusion during percutaneous microwave ablation and to assess the effect of vessel diameter, number, and patency, on ablation zone volume.Materials and MethodsComputed tomography (CT) fluoroscopy-guided percutaneous microwave ablations were performed in 8 pigs under general anesthesia. All ablations were performed at 65 W for 5 min with a single 17-gauge antenna positioned in the central third of the lungs. A CT pulmonary angiogram was performed immediately after the ablations. The maximum diameter, number and patency of PA branches within each ablation zone were recorded. Ablation volumes were measured at gross dissection and with CT. Student’s t test was used to compare ablation zone volumes among groups.ResultsTwenty-one pulmonary ablations were performed. Six of the ablation zones (29%) contained at least 1 occluded PA branch. The mean diameter of the occluded PA branches in the ablation zones (2.4 mm; range, 2.0–2.8 mm) was significantly smaller than non-occluded PA branches (3.7 mm; range: 2.1–6.9 mm; p = 0.009). No PA branches ≥3 mm in size were occluded. There was no significant difference in volume of gross ablation zones that contained occluded versus non-occluded PAs (p = 0.42), one versus multiple PAs (p = 0.71), or PAs <3 mm versus ≥3 mm in diameter (p = 0.44).ConclusionsPAs ≥3 mm in size have a low risk for iatrogenic occlusion during percutaneous microwave ablation. The presence of multiple adjacent PA branches, an occluded PA branch, and a vessel diameter ≥3 mm within the ablation zone had no observed effect on ablation zone volume.

Keywords: ablation; ablation zone; vessel diameter; microwave ablation; occlusion; diameter

Journal Title: CardioVascular and Interventional Radiology
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.