LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Quantitative Characterization of Recanalization and Distal Emboli with a Novel Thrombectomy Device

Photo from wikipedia

Purpose The first-pass effect during mechanical thrombectomy improves clinical outcomes regardless of first-line treatment approach, but current success rates for complete clot capture with one attempt are still less than… Click to show full abstract

Purpose The first-pass effect during mechanical thrombectomy improves clinical outcomes regardless of first-line treatment approach, but current success rates for complete clot capture with one attempt are still less than 40%. We hypothesize that the ThrombX retriever (ThrombX Medical Inc.) can better engage challenging clot models during retrieval throughout tortuous vasculature in comparison with a standard stent retriever without increasing distal emboli. Materials and Methods Thrombectomy testing with the new retriever as compared to the Solitaire stent retriever was simulated in a vascular replica with hard and soft clot analogs to create a challenging occlusive burden. Parameters included analysis of distal emboli generated per clot type, along with the degree of recanalization (complete, partial or none) by retrieval device verified by angiography. Results The ThrombX device exhibited significantly higher rates of first-pass efficacy (90%) during hard clot retrieval in comparison with the control device (20%) ( p  < 0.009), while use of both techniques during soft clot retrieval resulted in equivalent recanalization. The soft clot model generated higher numbers of large emboli (>200 μm) across both device groups ( p  = 0.0147), and no significant differences in numbers of distal emboli were noted between the ThrombX and Solitaire techniques. Conclusions Irrespective of clot composition, use of the ThrombX retriever demonstrated high rates of complete recanalization at first pass in comparison with a state-of-the-art stent retriever and proved to be superior in the hard clot model. Preliminary data suggest that risk of distal embolization associated with the ThrombX system is comparable to that of the control device.

Keywords: clot; recanalization; distal emboli; retriever; device

Journal Title: CardioVascular and Interventional Radiology
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.