LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Characteristics of screen-detected cancers following concordant or discordant recalls at blinded double reading in biennial digital screening mammography

Photo from wikipedia

ObjectivesTo analyse which mammographic and tumour characteristics led to concordant versus discordant recalls at blinded double reading to further optimise our breast cancer screening programme.MethodsWe included a consecutive series of… Click to show full abstract

ObjectivesTo analyse which mammographic and tumour characteristics led to concordant versus discordant recalls at blinded double reading to further optimise our breast cancer screening programme.MethodsWe included a consecutive series of 99,013 screening mammograms obtained between July 2013 and January 2015. All mammograms were double read in a blinded fashion. Discordant readings were routinely recalled without consensus or arbitration. During the 2-year follow-up, relevant data of the recalled women were collected. We compared mammographic characteristics, screening outcome and tumour characteristics between concordant and discordant recalls.ResultsThere were 2,543 concordant recalls (71.4%) and 997 discordant recalls (28.0%). The positive predictive value of a concordant recall was significantly higher (23.5% vs. 10.0%, p < 0.001). The proportion of BI-RADS 0 was significantly higher in the discordant recall group (75.7% vs. 56.3%, p < 0.001). Discordant recalls were more often an asymmetry or architectural distortion (21.8% vs. 13.2% and 9.3% vs. 6.5%, respectively, p < 0.001). There were no differences in the distribution of DCIS and invasive cancers and tumour characteristics were comparable for the two groups, except for a more favourable tumour grade in the discordant recall group (54.7% vs. 39.9% grade I tumours, p = 0.022).ConclusionsScreen-detected cancers detected by a discordant reading show a more favourable tumour grade than cancers diagnosed after a concordant recall. The higher proportion of asymmetries and architectural distortions in this group provide a possible target for improving screening programmes by additional training of screening radiologists and the implementation of digital breast tomosynthesis.Key Points• With blinded double reading of screening mammograms, screen-detected cancers detected by a discordant reading show a more favourable tumour grade than cancers diagnosed after a concordant recall.• The proportions of asymmetries and architectural distortions are higher in case of a discordant reading.• Possible improvement strategies could target additional training of screening radiologists and the implementation of digital breast tomosynthesis in breast cancer screening programmes.

Keywords: blinded double; double reading; detected cancers; discordant recalls; tumour

Journal Title: European Radiology
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.