LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Clinical impact of a new cone beam CT angiography respiratory motion artifact reduction algorithm during hepatic intra-arterial interventions

Photo by thisisengineering from unsplash

Objectives To assess the impact of recently developed respiratory motion correction software on contrast-enhanced cone beam CT angiography (CBCT-a) for intraprocedural image guidance during intra-arterial liver-directed therapy. Methods From 2015… Click to show full abstract

Objectives To assess the impact of recently developed respiratory motion correction software on contrast-enhanced cone beam CT angiography (CBCT-a) for intraprocedural image guidance during intra-arterial liver-directed therapy. Methods From 2015 to 2017, two groups of patients who underwent intra-arterial liver-directed therapy with ( breathing , n  = 30) or without ( still , n  = 30) significant respiratory motion artifacts were retrospectively included. All CBCT-a were processed with and without dedicated respiratory motion correction software. Four readers independently assessed the following in both reconstructions (motion correction ON and OFF ): (1) overall image quality on a 0-to-5 point scale, and (2) presence of relevant peri-procedural information on tumor and vasculature (overall vessel geometry, visibility of extrahepatic vessels, target tumor conspicuity, visibility of tumor feeders). Results Motion correction increased the average image quality in the breathing group from 2.0 ± 0.9 to 2.9 ± 1.0 ( p  < 0.01). The visibility of vessel geometry, extrahepatic vessels, and tumor feeders was significantly improved for all readers, and tumor conspicuity was improved for three readers. The average image quality was not significantly different between reconstructions in the still group (motion correction ON and OFF ), for any of the readers (4.0 ± 0.6 vs 4.2 ± 0.6; p  = 0.12). There was no change in the visibility of vessel geometry, extrahepatic vessels, tumor feeders, or tumor conspicuity for the four readers using the respiratory motion correction software in this group. Conclusions Using the dedicated respiratory motion correction software during intra-arterial liver-directed procedures increases the visualization of relevant peri-procedural information and image quality in CBCT-a corrupted by respiratory motion artifacts without affecting these elements in still CBCT-a. Key Points • The use of respiratory motion correction software could reduce the need for cone beam CT angiography acquisition retake. • Motion correction software significantly increases the visibility of vessel geometry, extrahepatic vessels, and tumor feeders, as well as tumor conspicuity in cone beam CT angiography corrupted by respiratory motion artifacts. • The use of respiratory motion correction software on cone beam CT angiography uncorrupted by respiratory motion artifact does not result in decreased image quality.

Keywords: motion; motion correction; correction software; geometry; respiratory motion

Journal Title: European Radiology
Year Published: 2019

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.