The role of cardiac CT throughout the full cardiac cycle in diagnosing patent foramen ovale in patients with acute stroke

Photo from wikipedia

We explored the hypothesis that the diagnostic performance of cardiac computed tomography (CT) throughout the full cardiac cycle would be superior to single-phase CT and comparable to transesophageal echocardiography (TEE)… Click to show full abstract

We explored the hypothesis that the diagnostic performance of cardiac computed tomography (CT) throughout the full cardiac cycle would be superior to single-phase CT and comparable to transesophageal echocardiography (TEE) in diagnosing patent foramen ovale (PFO). From May 2011 to April 2015, 978 patients with stroke were diagnosed with PFO by TEE. In patients with stroke, cardiac CT was performed if the patients had more than two cardiovascular risk factors. We prospectively enrolled 70 patients with an indication for cardiac CT. Cardiac CT images were reconstructed at 10% increments of the R-R interval. The sensitivity of cardiac CT throughout the full cardiac cycle in diagnosing PFO was compared to that for TEE and single-phase cardiac CT. To evaluate the specificity of cardiac CT, we analyzed patients without PFO confirmed by TEE who underwent cardiac CT within 1 month of pre-cardiac surgery. Sixty-six patients with cardiac CT and TEE were included in the final analysis. Throughout the full cardiac cycle, cardiac CT had a sensitivity of 89.4% and a specificity of 92.3% in diagnosing PFO, compared to TEE as a reference. PFO was primarily detected in the 60% and 70% intervals in 10-phase reconstructed images. The sensitivity of PFO diagnosis with cardiac CT was 81.8% when analyzing both the 60% and 70% intervals instead of the full cardiac cycle. Cardiac CT throughout the full cardiac cycle outperforms single-phase cardiac CT in detecting PFO. Cardiac CT can be used as an alternative method to TEE for detecting PFO in stroke patients. • Throughout the full cardiac cycle, cardiac computed tomography (CT) had a sensitivity of 89.4% and a specificity of 92.3% in diagnosing patent foramen ovale (PFO), compared to transesophageal echocardiography. • The sensitivity of diagnosing patent foramen ovale with cardiac CT was 81.8% when analyzing 60% and 70% R-R intervals instead of the full cardiac cycle. • Cardiac CT with retrospective electrocardiographic gating throughout the full cardiac cycle can increase the detectability of PFO, compared to single-phase cardiac CT.

Keywords: tee; full cardiac; throughout full; cardiac cycle

Journal Title: European Radiology
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.