LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Prospective validation of an acoustic-based system for the detection of obstructive coronary artery disease in a high-prevalence population

Photo from wikipedia

Recent guidelines recommend a risk-adjusted, non-invasive work-up in patients presenting with chest discomfort to exclude coronary artery disease (CAD). However, a risk-adjusted diagnostic approach remains challenging in clinical practice. An… Click to show full abstract

Recent guidelines recommend a risk-adjusted, non-invasive work-up in patients presenting with chest discomfort to exclude coronary artery disease (CAD). However, a risk-adjusted diagnostic approach remains challenging in clinical practice. An acoustic detection device for analyzing micro-bruits induced by stenosis-generated turbulence in the coronary circulation has shown potential for ruling out CAD in patients with low-to-intermediate likelihood. We examined the diagnostic value of this acoustic detection system in a high-prevalence cohort. In total, 226 patients scheduled for clinically indicated invasive coronary angiography (ICA) were prospectively enrolled at two centers and examined using a portable, acoustic detection system. The acoustic analysis was performed in double-blinded fashion prior to quantitative ICA and following percutaneous coronary intervention (PCI). An acoustic detection result (CAD score) was obtained in 94% of all patients. The mean baseline CAD score was 41.2 ± 11.9 in patients with obstructive CAD and 33.8 ± 13.4 in patients without obstructive CAD (p < 0.001). ROC analysis revealed an AUC of 0.661 (95% CI 0.584–0.737). Sensitivity was 97.6% (95% confidence interval (CI) 91.5–99.7%), specificity was 14.5% (CI 9.0–21.7%), negative predictive value was 90.5% (CI 69.6–98.8%), and positive predictive value was 41.7% (CI 34.6–49.0%). Following PCI, the mean CAD score decreased from 40.5 ± 11.2 to 38.3 ± 13.7 (p = 0.039). Using an acoustic detection device identified individuals with CAD in a high-prevalence cohort with high sensitivity but relatively low specificity. The negative predictive value was within the predicted range and may be of value for a fast rule-out of obstructive CAD even in a high-prevalence population.

Keywords: detection; high prevalence; cad; value; acoustic detection

Journal Title: Heart and Vessels
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.