Geometric analysis and clinical outcome of two cemented stems for primary total hip replacement with and without modular necks

Photo from wikipedia

IntroductionRestoration of the physiological biomechanical principles of the hip is crucial in total hip replacement. The aim of this study was to compare an arthroplasty system with different offset options… Click to show full abstract

IntroductionRestoration of the physiological biomechanical principles of the hip is crucial in total hip replacement. The aim of this study was to compare an arthroplasty system with different offset options (a: Exeter®) with a dual-modular stem (b: Profemur Xm®).Materials and methodsA local and an inertial coordinate system were used to assist the description of the components’ assembly in the prosthesis. A resection line of the femoral head in standard position was added to the arthroplasties and geometric parameters were measured. The outcomes of 93 patients were clinically evaluated (a: n = 50, b: n = 43). Preoperative planning was compared to postoperative radiographs (femoral offset, leg-length), and clinical scores (HHS, WOMAC, total range of motion) were assessed preoperatively, and then 1 and 2 years after surgery.ResultsThe Exeter® offers an offset range from 32.1 to 56.9 mm and the Profemur Xm® a range from 29.3 to 55.3 mm. The leg-length variability of the Profemur Xm® has a range of 25.9 mm, the Exeter® a range of 13.7 mm. The Profemur Xm® offers more possible combinations of offset and leg-length reconstruction. The neck–stem angles of the Exeter® range from 125.2° to 126.3°, of the Profemur Xm® from 127.2° to 142.6°. There was no statistically significant difference in clinical outcome and radiological parameters.ConclusionsWe conclude that both stems offer a wide range of options for anatomical reconstruction of the hip resulting in similarly good clinical results. The Profemur Xm® stem has advantages for the reconstruction of hips that deviate from standard anatomy but has the drawback of additional corrosive wear at the stem/neck interface.

Keywords: range; hip; hip replacement; clinical outcome; total hip

Journal Title: Archives of Orthopaedic and Trauma Surgery
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.