LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Periprosthetic acetabular radiolucency progression in mid-term follow-up of the articular surface replacement hip system

Photo by majestical_jasmin from unsplash

IntroductionRecent registry studies show that aseptic loosening secondary to osteolysis is the second leading cause of hip implant failure in patients implanted with metal-on-metal (MoM) bearings. The primary aim of… Click to show full abstract

IntroductionRecent registry studies show that aseptic loosening secondary to osteolysis is the second leading cause of hip implant failure in patients implanted with metal-on-metal (MoM) bearings. The primary aim of our study was to report on the progression of acetabular osteolysis during mid-term follow-up in patients treated with MoM hip resurfacing arthroplasty (HRA) and MoM total hip arthroplasty (THA). The secondary aim was to identify independent predictors of osteolytic lesion progression.Materials and methodsA total of 805 patients (805 hips) were included in this study (541 MoM HRA, 264 MoM THA) from a prospective, international clinical registry of the Articular Surface Replacement Hip System. Patients were enrolled a median of 6.6 years from surgery. Osteolytic lesion progression was defined either as any lesion developing de novo, or as an existing lesion progressing from radiolucency to osteolysis during the study period (range 0.5–4.3 years).ResultsThe number of cases with any osteolysis or radiolucency was 21 (3.9%) for ASR HRA and 29 (11.0%) for ASR XL THA at enrollment and increased to 69 (12.8%) for ASR HRA and 41 (15.5%) for ASR XL THA after follow-up. Osteolytic lesion progression was found in 66 (12.2%) ASR HRA patients and 31 (11.7%) ASR XL THA patients. Multivariate models determined that lower acetabular version angle (OR 0.963, p = 0.011) and elevated whole blood chromium (OR 1.110, p = 0.044) were independent predictors of osteolytic lesion progression in ASR HRA.ConclusionWe suggest that physicians of patients implanted with ASR HRA implants closely monitor patients with higher chromium levels and lower version angles, as they are at increased risk for osteolytic lesion progression, and we recommend annual radiographic follow-up on all patients with ASR implants.

Keywords: osteolytic lesion; hip; hra; lesion progression; progression

Journal Title: Archives of Orthopaedic and Trauma Surgery
Year Published: 2018

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.