LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Effect of Balloon Pulmonary Angioplasty on Homogenization of Lung Perfusion Blood Volume by Dual-Energy Computed Tomography in Patients with Chronic Thromboembolic Pulmonary Hypertension

Photo by nhiamoua from unsplash

Balloon pulmonary angioplasty (BPA) is used to treat patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH); the goal is to improve pulmonary perfusion. We aimed to evaluate lung perfusion blood… Click to show full abstract

Balloon pulmonary angioplasty (BPA) is used to treat patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH); the goal is to improve pulmonary perfusion. We aimed to evaluate lung perfusion blood volume (PBV) with haemodynamic and exercise-capacity parameters to assess the efficacy of BPA in the treatment of CTEPH. We retrospectively studied 33 patients over a 6-year period. DECT pulmonary angiography was performed before and after BPA. DECT provided iodine distribution maps; whole-lung and regional PBV images and quantification were generated using post-processing software. A mosaic pattern suggesting perfusion inhomogeneity is typical in CTEPH. Hypothetically, BPA treatment would promote homogenization that would be reflected in the calculated standard deviation. Lung perfusion images showed decreased heterogeneity after BPA. There was a significant difference before and after BPA in the whole-lung PBV and in the regional standard deviation for pulmonary arterial pressure (R = 0.37, p = 0.032 and R = 0.57, p = 0.006), pulmonary vascular resistance (R = 0.51, p = 0.023 and R = 0.60, p = 0.002), transtricuspid pressure gradient (R = 0.50, p = 0.0028 and R = 0.61, p = 0.0001), brain natriuretic peptide (R = 0.54, p = 0.0012 and R = 0.46, p = 0.0078), and 6-min walking distance (R = 0.59, p = 0.003 and R = 0.26, p = 0.14). The effects were especially pronounced after the first BPA procedure. Decreased lung heterogeneity may suggest BPA efficacy in treating CTEPH. After BPA treatment, improved lung PBV and improved regional standard deviation showed a strong positive correlation with haemodynamic parameters and exercise capacity, which also suggests that BPA is effective in treating CTEPH.

Keywords: pulmonary angioplasty; lung perfusion; perfusion; bpa; balloon pulmonary; lung

Journal Title: Lung
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.