LAUSR.org creates dashboard-style pages of related content for over 1.5 million academic articles. Sign Up to like articles & get recommendations!

Automated digital analysis of intraoperative keratoscopy and its correlation with postoperative astigmatism after big-bubble deep anterior lamellar keratoplasty

Photo by neom from unsplash

Purpose To investigate the correlation between postoperative corneal astigmatism (PCA) and values of intraoperative keratoscopy analyzed with a newly developed automated technique in patients undergoing big-bubble (BB) deep anterior lamellar… Click to show full abstract

Purpose To investigate the correlation between postoperative corneal astigmatism (PCA) and values of intraoperative keratoscopy analyzed with a newly developed automated technique in patients undergoing big-bubble (BB) deep anterior lamellar keratoplasty (DALK). Methods Photographs of keratoscope rings taken at the end of BB-DALK were analyzed using ImageJ for the calculation of “roundness” ( R ): values = 1 indicate a perfect circle. Pearson’s correlation was used to evaluate the relationship between R and PCA that measured 1 week (V1), 3 months (V2), and 18 months (V3), postoperatively. The area under the curve (AUC) of receiver operating characteristic (ROC) curve was used to evaluate the accuracy of R for identifying patients with PCA < 3 diopters (D). The point on the ROC curve nearest to the coordinate (0,100) was used as a cutoff to determine sensitivity and specificity. Results Data from 121 patients were included. The mean value of R *was 0.93 ± 0.04 (range 0.76–0.99). R showed a significant correlation with PA at V3 ( R  = − 0.42, P  < 0.01). The ROC curve had an AUC of 0.69 (95% CI 0.59–0.79). A cutoff value of R  = 0.93 had a sensitivity of 70.3% and specificity of 61.0% for identifying patients with PA < 3D at V3. Conclusions This new digital analysis of keratoscope rings allows to identify with reasonably good diagnostic accuracy patients with low values of post-DALK astigmatism correctable with spectacles.

Keywords: big bubble; correlation postoperative; bubble deep; correlation; intraoperative keratoscopy; astigmatism

Journal Title: Graefe's Archive for Clinical and Experimental Ophthalmology
Year Published: 2020

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.