Comparison of 1-year surgical outcomes of combined cataract surgery and gonioscopy-assisted transluminal trabeculotomy (GATT) versus cataract surgery and iStent Inject

Photo by goian from unsplash

Evaluate the efficacy, safety, and complication rates of phacoemulsification cataract surgery when combined with either gonioscopy-assisted transluminal trabeculotomy (GATT) or iStent Inject. This is a retrospective case-control study to compare… Click to show full abstract

Evaluate the efficacy, safety, and complication rates of phacoemulsification cataract surgery when combined with either gonioscopy-assisted transluminal trabeculotomy (GATT) or iStent Inject. This is a retrospective case-control study to compare the surgical outcomes of combined phacoemulsification cataract surgery with either GATT (phaco-GATT) or iStent Inject (phaco-iStent). Both groups had at least 1-year follow-up. The primary outcome measures were IOP and number of glaucoma medications (NGMs) at 1 year. Secondary outcomes measures were best corrected visual acuity (BCVA) and intra- or postoperative complications within the first year of follow-up. Success was defined as intraocular pressure (IOP) < 21 mmHg and ≥ 20% reduction in IOP at 1 year regardless of the NGM. Each group included 37 patients. The median baseline IOP (24 vs 17) and NGM (3 vs 2) were higher in the phaco-GATT group (p < 0.001). Phaco-GATT achieved a 38% (p < 0.0001) reduction in IOP compared to 13.2% (p < 0.001) in the phaco-iStent group at 1-year follow-up. The reduction in IOP and NGM was significantly higher in the phaco-GATT group (p < 0.01). After adjusting for baseline IOP, the reduction in IOP at 12 months was still significantly higher in the phaco-GATT group (p = 0.042). At 1 year, 86.4% of patients in the phaco-GATT group met the success criteria compared to 35.1% in the phaco-iStent group. Safety outcomes were slightly favourable in the phaco-iStent group. Phaco-GATT and phaco-iStent showed a significant reduction in IOP and NGM, with phaco-GATT having a significantly higher reduction. Phaco-iStent appears to have a higher safety profile and is probably preferable in monocular patients and those with a high risk of bleeding.

Keywords: istent; phaco gatt; year; cataract surgery

Journal Title: Graefe's Archive for Clinical and Experimental Ophthalmology
Year Published: 2021

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.