Point-of-care testing for coagulation function: CoaguChek® XS System versus standard laboratory testing in pediatric patients with normal and abnormal coagulation function

Photo by lucabravo from unsplash

PurposeIntraoperative abnormalities of coagulation function may occur for various reasons. In most scenarios, treatment is directed by laboratory parameters. Unfortunately, standard laboratory testing may take 1–2 h. The purpose of the… Click to show full abstract

PurposeIntraoperative abnormalities of coagulation function may occur for various reasons. In most scenarios, treatment is directed by laboratory parameters. Unfortunately, standard laboratory testing may take 1–2 h. The purpose of the current study was to evaluate a point-of-care testing device (CoaguChek® XS System) in pediatric patients.MethodsPatients ranging in age from 2 to 18 years, undergoing posterior spinal fusion (PSF) or cardiac surgery using cardiopulmonary bypass (CPB) were eligible for inclusion. After CPB and/or the surgical procedure, 2.8 ml of blood was obtained and simultaneously tested on both the standard laboratory apparatus and the CoaguChek® XS System.ResultsThe study cohort consisted of 100 patients (50 PSF and 50 cardiac cases) with 13 cases excluded, leaving 87 patients (49 PSF and 38 cardiac cases) for analysis. In PSF cases, reference laboratory international normalized ratio (INR) ranged from 0.98 to 1.77 while CoaguChek® XS INR ranged from 1.0 to 1.3. The correlation coefficient was 0.69. The results of the Bland–Altman analysis showed a bias of 0.09, precision of 0.1, and 95% limits of agreement ranging from −0.11 to 0.28. In cardiac cases, reference INR ranged from 1.68 to 14.19, while CoaguChek® XS INR ranged from 1.4 to 7.9. The correlation coefficient was 0.35. The results of the Bland–Altman analysis showed a bias of −1.8, precision of 2.1, and 95% limits of agreement ranging from −6.0 to 2.4.ConclusionsINR values obtained from CoaguChek® XS showed a moderate correlation with reference laboratory values within the normal range. However, in the presence of coagulopathy, the discrepancy was significantly greater, thereby making the CoaguChek® XS clinically unreliable.

Keywords: coagulation; coagulation function; coaguchek; standard laboratory

Journal Title: Journal of Anesthesia
Year Published: 2017

Link to full text (if available)


Share on Social Media:                               Sign Up to like & get
recommendations!

Related content

More Information              News              Social Media              Video              Recommended



                Click one of the above tabs to view related content.